Table 3-3Keyboard Commands (Terminal Emulation Programs Only)

User Interface Features

Table 3-3Keyboard Commands (Terminal Emulation Programs Only)

Keystroke

Function

 

 

1-8

Select inverter: 1 through 8 is the inverter’s ID

number, 1 is the default.

 

Setup Menu - Accesses either “BEGIN BASIC

SSETUP” or “BEGIN ADVANCED SETUP” Menus.

 

Sends ASCII LED Status. The information

 

displayed on the screen mimics the layout of the

 

LEDs on the inverter control module : each LED is

 

represented by a dash or a character, laid out in two

? or /

rows of four characters.

• Dash: the LED is not lit.

 

 

Non-blinking character: the LED is solid (lit).

 

• Blinking character: the LED is blinking.

 

See Sine Wave Plus Inverter/Charger Owner's

 

Manual for details.

 

 

V, v

Version number of ICA

 

 

T, t

Set terminal mode. If you see a display of many

strange characters, try pressing “T” to clear it up.

 

~Adapter Reset

ESC

Retransmit LCD screen, LED’s, and Adapter ID

number

 