Table 2: IBA_PLBv46 Design Parameters (Continued)
Generic | Feature/Description | Parameter Name | Allowable Values | Default | VHDL |
|
Value | Type |
| ||||
|
|
|
|
| ||
|
|
|
|
|
|
|
G46 | 1=Enable storing MU 6 signals in the data | C_MU_6_EN_STORE_SLV_ | 0,1 | 1 | Integer |
|
| sample storage buffer. | CTL_BUS |
|
|
|
|
| 0=Disable |
|
|
|
|
|
| C_USE_MU_6A_SLV_CTL or |
|
|
|
|
|
| C_USE_MU_6B_SLV_SZ_WADDR must |
|
|
|
|
|
| be 1 in order to store. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| Slave Busy Status |
|
|
|
|
|
|
|
|
|
|
|
G47 | USE SI_MBusy signal | C_USE_MU_7_SLV_BSY | 1,0 | 0 | Integer |
|
|
|
|
|
|
|
|
G48 | 0=basic, 1=basic w/ edges | C_MU_7_TYPE_SLV_BSY | 0,1 | 0 | Integer |
|
|
|
|
|
|
|
|
G49 | Match unit counter width. 0 means do not | C_MU_7_CNT_W_SLV_BSY | 0 | Integer |
| |
| use |
|
|
|
|
|
|
|
|
|
|
|
|
G50 | 1=Enable storing MU 7 signals in the data | C_MU_7_EN_STORE_SLV_ | 0,1 | 1 | Integer |
|
| sample storage buffer. | BSY |
|
|
|
|
| 0=Disable |
|
|
|
|
|
| C_USE_MU_7_SLV_BSY must be 1 in |
|
|
|
|
|
| order to store. |
|
|
|
|
|
|
|
|
|
|
|
|
| Slave Read/Writer Error Status |
|
|
|
| |
|
|
|
|
|
|
|
G51 | Use SI_MRdErr | C_USE_MU_8_SLV_RD_ERR | 1,0 | 0 | Integer |
|
|
|
|
|
|
|
|
G52 | 0=basic, 1=basic w/ edges | C_MU_8_TYPE_SLV_RD_ | 0,1 | 0 | Integer |
|
|
| ERR |
|
|
|
|
|
|
|
|
|
|
|
G53 | Match unit counter width. 0 means do not | C_MU_8_CNT_W_SLV_RD_ | 0 | Integer |
| |
| use | ERR |
|
|
|
|
|
|
|
|
|
|
|
G54 | 1=Enable storing MU 8 signals in the data | C_MU_8_EN_STORE_SLV_ | 0,1 | 1 | Integer |
|
| sample storage buffer. | RD_ERR |
|
|
|
|
| 0=Disable |
|
|
|
|
|
| C_USE_MU_8_SLV_RD_ERR must be 1 |
|
|
|
|
|
| in order to store. |
|
|
|
|
|
|
|
|
|
|
|
|
G55 | Use SI_MWrErr | C_USE_MU_9_SLV_WR_ERR | 1,0 | 0 | Integer |
|
|
|
|
|
|
|
|
G56 | 0=basic, 1=basic w/ edges | C_MU_9_TYPE_SLV_WR_ | 0,1 | 0 | Integer |
|
|
| ERR |
|
|
|
|
|
|
|
|
|
|
|
G57 | Match unit counter width. 0 means do not | C_MU_9_CNT_W_SLV_WR_ | 0 | Integer |
| |
| use | ERR |
|
|
|
|
|
|
|
|
|
|
|
G58 | 1=Enable storing MU 9 signals in the data | C_MU_9_EN_STORE_SLV_ | 0,1 | 1 | Integer |
|
| sample storage buffer. | WR_ERR |
|
|
|
|
| 0=Disable |
|
|
|
|
|
| C_USE_MU_9_SLV_WR_ERR must be 1 |
|
|
|
|
|
| in order to store. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| PLB Arbitration |
|
|
|
|
|
|
|
|
|
|
|
G59 | Use Master arbitration signals | C_USE_MU_10_ARB_CTL | 1,0 | 0 | Integer |
|
|
|
|
|
|
|
|
G60 | 0=basic, 1=basic w/ edges | C_MU_10_TYPE_ARB_CTL | 0,1 | 0 | Integer |
|
|
|
|
|
|
|
|
G61 | Match unit counter width. 0 means do not | C_MU_10_CNT_W_ARB_CTL | 0 | Integer |
| |
| use |
|
|
|
|
|
|
|
|
|
|
|
|
G62 | 1=Enable storing MU 10 signals in the data | C_MU_10_EN_STORE_ARB_ | 0,1 | 1 | Integer |
|
| sample storage buffer. | CTL |
|
|
|
|
| 0=Disable |
|
|
|
|
|
| C_USE_MU_10_ARB_CTL must be 1 in |
|
|
|
|
|
| order to store. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
DS619 (v1.0) September 17, 2007 | www.xilinx.com |
|
|
|
| |
Product Specification |
|
|
| 8 |