| Administrative Tasks |
|
|
|
Variable Name | Default | Description |
|
|
|
XAPPLRESDIR | default path | The path to the defaults for all of the GUI |
| (identified by | windows is defined by this variable. If this |
| $VS_DIR/default | variable is not set, the defaults must be put |
| s) | in |
|
| directory. |
|
|
|
VSRPT_PAGE_LENGTH | 0 | The page length for the query report in |
|
| vsadm. If set to 0, no page breaks and |
|
| subsequent page headers are inserted. |
|
| Typical page length is 66. |
|
|
|
Process Server | The following table shows the variables that can be modified, as | ||||
Defaults | required, to change the software communications. VolServ must | ||||
| be cycled for the changes to become effective. | ||||
|
|
|
|
|
|
Variable Name |
|
| Default | Description | |
|
|
|
|
| |
PROCSERV_TIMEOUT_VALUE |
| 4 |
| Number of seconds this process pauses | |
|
|
|
|
| between attempts to communicate with the |
|
|
|
|
| processes initiated by bringing up or |
|
|
|
|
| terminating VolServ. Increase if the processing |
|
|
|
|
| speed of the system is extremely slow. |
|
|
|
|
|
|
VolServ | The following table shows the variables that can be modified, as | ||||
Defaults | required, to change the time associated with activating and | ||||
| terminating VolServ. VolServ must be cycled for the changes to | ||||
| become effective. |
| |||
|
|
|
|
|
|
Variable Name |
|
| Default |
| Description |
|
|
| |||
VOLSERV_START_TIMEOUT | 600 | Timeout, in seconds, to wait for VolServ to start. | |||
|
|
|
| ||
VOLSERV_QUIT_TIMEOUT |
| 300 | Timeout, in seconds, to wait for VolServ to | ||
|
|
|
| terminate immediately. | |
|
|
|
|
|
|
Getting Started
601354 Rev A | Getting Started |