Trouble Recovery
ZMU02614
TIP:
When the engine does not start with this pro- cedure, see page 77.
EMU29671
Engine fails to operate
EMU29691
Ignition system malfunctionIf the battery voltage is low or in the unlikely event of an ignition system malfunction, the engine speed may become erratic or the engine may stop. In such a situation, follow the procedure below.
1.Remove the CDI unit cover or electrical cover, if equipped.
2.Disconnect the yellow cord (emergency
circuit) of the CDI unit to return to port.
EWM00350
WARNING
When the yellow cord is disconnected, the idle and low speeds are slightly higher than normal. Use care when starting off or stopping.
ECM00380
NOTICE
Follow this procedure only in an emergency and just long enough to return to port for repairs.
1
| 1 |
|
|
2 |
| 2 |
|
|
|
| |
|
| ZMU03843 | |
|
|
| |
|
|
|
|
1.CDI unit
2.Emergency connector
EMU29706
Cold engine fails to startIf the engine fails to start when it is cold, use the following procedure.
EWM00410
WARNING
When starting or operating the engine, do not touch the ignition coil, spark plug wire, spark plug cap, or other electrical parts carrying high voltage. Keep loose clothing and other objects away from the engine when starting it. Do not touch the flywheel or other moving parts when the engine is running.
1.Adjust the trim angle so that the drive shaft is at right angles to the water sur- face or is trimmed in.
2.On models equipped with an emergency starter valve, open it. The valve is locat- ed behind the silencer cover on the front of the engine.
77