YMF715E
Sound Blaster compatibility Internal State Scan out/in (R/W):
Index |
| D7 | D6 | D5 |
| D4 |
| D3 | D2 | D1 |
| D0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
10h |
| SBPDA | - | - |
| - |
| SS | SM | SE |
| SBPDR |
SBPDA... | Sound Blaster Power Down Acknowledgment: “1” in SBPDA acknowledges | |||||||||||
|
| that | ||||||||||
|
| down operation. This flag is |
|
|
|
|
| |||||
SS... | Scan Select : Set “1” in this bit when reading or writing internal state. |
| ||||||||||
|
| Set “0” for normal operation. |
|
|
|
|
|
|
| |||
SM... | Scan Mode : Setting “1” in this bit means the internal state’s are read(out). | |||||||||||
|
| Set “0” for write(in). |
|
|
|
|
|
|
| |||
SE... | Scan Enable : “1” to “0” transition in this bit clocks the shifting internal state | |||||||||||
|
| scan data out |
|
|
|
|
|
|
| |||
SBPDR... | Sound Blaster Power Down Request : “1” in this bit inhibits further DMA | |||||||||||
|
| requests and have the internal state begin shutdown procedure. “1” in | ||||||||||
|
| SBPDA signals the shutdown procedure completion. |
|
|
|
default : 00h
Sound Blaster compatibility Internal State Scan Data (R/W):
Index | D7 | D6 | D5 | D4 | D3 | D2 | D1 | D0 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
11h |
|
|
| SCAN DATA |
|
|
|
SCAN DATA... Data port for internal state scan data in/out. default : 00h
Notice)
The Sound Blaster compatibility internal state scan out/in sequence are shown in the following
May 21, 1997