![](/images/new-backgrounds/1010023/1002339x1.webp)
SERVICING INSTRUCTIONS
REPLACING PARTS
9.Gazco flue sure system
9.1Open the door and remove the ceramics, placing them carefully to one side. Undo the two screws in the back of the firebox and carefully withdraw the bracket (see Diagram 14).
14
AR1442
9.2Disconnect the two sender wires. Undo the two taptite screws and remove the sensor and the two plastic spacers (see Diagram 15).
15
AR1446
9.3Refit the new sensor ensuring that the plastic spacers are located between the bracket and the sensor. Refit the leads (see Diagram 16).
16
9.4Feed the cable back through the hole as you replace the bracket. When the bracket is located correctly it will sit flush with the back panel without force being required. If not positioned correctly the bracket will sit at an angle (see Diagram 17).
17
AR1447 | AR1448 |
10.Primary aeration plate
10.1Remove the cover plate from the bottom of the stove by undoing the 6mm bolt (see Diagram 18).
18 |
AR1449 |
10.2Undo the M5 nyloc nut from the bottom of the burner unit and remove the aeration plate (see Diagram 19).
19
AR1452
AR1441
10.3 Reassemble in reverse order with the correct aeration plate.
20