Yeoman YM-E9001FLA manual Servicing Requirements

Models: YM-E9001FLA

1 14
Download 14 pages 47.31 Kb
Page 10
Image 10
SERVICING

SERVICING

SERVICING REQUIREMENTS

THIS APPLIANCE MUST ONLY BE SERVICED BY A SUITABLY QUALIFIED PERSON.

BEFORE UNDERTAKING ANY WORK ON THE

APPLIANCE:

1.1Switch off the appliance and isolate it from the mains by unplugging the unit.

1.2Wait for at least 10 minutes until the appliance has cooled down.

1.3Following the appropriate instructions from User Instructions, Section 4, remove the door and glass front.

1.4Remove the screws on the lower panel on the front of the appliance and carefully remove the fuel bed (see Diagram 5).

Please note: The fuel bed is secured by 2 x screws on the lower panel on the front of the stove.

5

Screws

Fuel bed

 

 

 

 

AR2391

REPLACING FRONT LED BOARD

1.5If an LED fails to light you will notice an uneven or unlit fuel effect. To replace the front LED board (for middle and rear boards see 1.21 onward):

1.6Disconnect all wires from the front LED board, noting their orientation.

1.7The board is secured by 2 x plastic push fasteners (see Diagram 6). Using pliers, gently squeeze the head of the fasteners to release the board.

6

Push fasteners

Front LED

 

board

 

Plugs

AR2393

 

1.8Dispose of the board at an appropriate recycling centre.

1.9To connect the new LED board push the fasteners

through the ready drilled holes and ensure that all wires are correctly connected.

REPLACING THE PRINTED CIRCUIT BOARD

1.10To remove the PCB first remove the front LED board following instructions 1.6 & 1.7.

1.11The PCB is fixed to the base of the appliance using 2 x push fasteners and 2 x screws (see Diagram 7). Release board from fasteners and remove screws.

7

PCB

AR2392

1.12The wires should now be disconnected from the PCB one by one. As each wire is disconnected from the old PCB attach it to the new PCB to ensure correct orientation.

1.13Fix the new PCB to the base of the appliance using the 2 x push fasteners and 2 x screws.

10

Page 10
Image 10
Yeoman YM-E9001FLA manual Servicing Requirements