FILTERS
Unitary Products Group
Recip
CHARGE
FILTER
COMPRESSOR
CONDENSER
COIL
CONDENSER
FAN
EVAPORATOR
COIL
EVAPORATOR
BLOWER
CENTRIFUGAL BLOWER (Dia. x Wd. in.) FAN MOTOR HP (Three Speed)
ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) PROPELLER DIA. (in.)
FAN MOTOR HP
NOM. CFM TOTAL ROWS DEEP FINS PER INCH FACE AREA (Sq. Ft.) REFRIGERANT 22 (lbs./oz.) FACE AREA (Sq. Ft. / Qty. / Size) HERMETIC Type, (Qty. = 1)
MODELS
TABLE 3 - PHYSICAL DATA
NOTE: Be sure to note supply and return openings.
Refer to Figure 3 for information concerning rear and bottom 1 supply and return air duct openings.
0181
9 X 6
2
2
13
2.19
22
4
1,800
1
18
8.3
3 / 4
CLEARANCES
All units require certain clearances for proper operation and service. Refer to Figure 3 for the clearances required for com- bustion, construction, servicing and proper unit operation.
WARNING: Do not permit overhanging structures or shrubs to obstruct the condenser air discharge outlet.
DUCT WORK
These units are adaptable to downflow use as well as rear sup- ply and return air duct openings. To convert to downflow, use the following steps:
1. Remove the duct covers found in the bottom return and supply air duct openings. There are four (4) screws secur- ing each duct cover (save these screws to use later).
2. Install the duct covers, removed in step one, to the rear sup- ply and return air duct openings. Secure with the four (4) screws used in step one.
3. Seal the duct covers with silicone caulking.
Downflow units must have an L-shaped supply duct without any outlets or registers located directly below the supply outlet of the unit.
Duct work should be designed and sized according to the methods of the Air Conditioning Contractors of America (ACCA), as set forth in their Manual D.
A closed return duct system shall be used. This shall not pre- clude use of economizers or ventilation air intake. Flexible joints may be used in the supply and return duct work to mini- mize the transmission of noise.
CAUTION: When fastening duct work to the side duct flanges on the unit, insert the screws through the duct flanges only. DO NOT insert the screws through the casing. Outdoor duct work must be insulated and waterproofed.

035-16703-001-A-0202

FILTERS

Single phase units are shipped without a filter and is the responsi- bility of the installer to secure a filter in the return air ductwork or install a Filter/Frame Kit (1FF0114).

A filter rack and a filters are standard on three phase units.

Filters must always be used and must be kept clean. When fil- ters become dirt laden, insufficient air will be delivered by the blower, decreasing your units efficiency and increasing operat- ing costs and wear-and-tear on the unit and controls.

Filters should be checked monthly especially since this unit may be used for both heating and cooling.

CONDENSATE DRAIN

A condensate trap is required to be installed in the condensate drain. The plumbing must conform to local codes. Use a seal- ing compound on male pipe threads. Install the condensate drain line (34CONDENSATE DRAIN“ NPTF) to spill into an open drain.

SERVICE ACCESS

Access to all serviceable components is provided by the follow- ing removable panels:

Blower service access

Electrical/filter access

Compressor service access

Refer to Figure 3 for location of these access panels and mini- mum clearance.

THERMOSTAT

The room thermostat should be located on an inside wall ap- proximately 56" above the floor where it will not be subject to drafts, sun exposure or heat from electrical fixtures or appli- ances. Follow manufacturer's instructions enclosed with the thermostat for general installation procedure. Four or five color coded insulated wires (minimum #18 AWG) should be used to connect thermostat to unit. See Figure 2.

DEB

 

 

024

030

036

042

048

060

 

 

 

10 X 8

10 X 8

10 x 8

11 X 10

11 x 10

11 x 10

 

 

 

12

12

3

4

3

4

3

4

1

 

 

 

2

2

2

2

2

3

 

 

 

15

15

15

15

13

16

 

 

 

2.81

4.38

4.38

4.38

5.62

5.26

 

 

 

22

22

22

22

22

22

 

 

 

14

14

14

14

14

14

 

 

 

2,200

2,400

2,400

2,400

2,800

2,800

 

 

 

1

1

1

1

1

1

 

 

 

16

20

18

16

13

20

 

 

 

8.3

8.3

8.3

11.7

16.4

16.4

 

 

 

3 / 5

3 / 13

3 / 10

4 / 7

5 / 15

5 / 15

 

 

 

 

2.14 / 2 / 14" x 22"

 

 

 

 

 

 

 

Recip

Recip

Recip

Recip

Scroll

Scroll

3

Page 3
Image 3
York 1-1/2 THRU 5 TON (10 SEER), D1EB018 THRU 060 Filters, Condensate Drain, Service Access, Thermostat