York K4EU090, K2EU060, K3EU120, K3EU180 UNIT DIMENSIONS KEU180 ACCESSORIES, UNIT CLEARANCES KEU180

Models: K3EU180 K4EU090 K3EU120 K2EU060

1 28
Download 28 pages 18.44 Kb
Page 18
Image 18
FIGURE 3 - UNIT DIMENSIONS KEU180
1-23/32"KNOCKOUT RemoveonlywhenElectric HeatAccessoryisused.

036-21300-002-A-0905

BLOWERMOTORANDDRIVEACCESSPANEL

(Alwaysonthewiringconnectionsideofunit)

LocatedonoppositesideONLYwhentheblower 7/8"KNOCKOUTFORPOWERWIRING

sectionhasbeenrotated180frompositionshown. DonotremovethisknockoutwhentheunitisequippedwithanElectric HeatAccessory.RefertodetailoftheHeaterAccessoryforpower

wiringaccessopening

 

 

7/8"KNOCKOUTFOR

 

 

 

CONTROLWIRING

 

 

60-3/4

 

 

 

19-3/8

21-7/8

 

ALTERNATE

 

 

2-5/8"KNOCKOUT*

 

AIR

 

 

 

5-7/8

 

 

OUT

 

 

 

 

 

 

 

 

 

5-1/2

2-1/8

 

7/8

 

18-7/8

 

7-1/4

6

32-3/8

 

16-1/2

 

 

 

 

 

 

 

BLOWER

3-1/8

2-5/8"

 

 

SECTION

 

 

19

 

 

KNOCK-

 

 

 

 

 

 

 

 

OUTFOR

 

 

 

 

1-5/8"OD

 

 

 

10

SUCTION

 

 

 

 

CONN.*

27-5/8

6-1/4

3-1/8

 

 

 

 

COIL

62-5/8

 

 

 

 

 

 

 

SECT.

3-1/8

 

 

 

 

2-3/8

AIR

 

 

 

 

IN

 

 

 

 

 

 

 

1-1/4"KNOCKOUT

 

 

 

 

FOR7/8"ODDRAIN

2-3/16

 

 

 

CONNECTION*

 

 

 

 

(Mustbetrapped)

 

56-3/8

 

 

FILTERACCESSPANEL

 

 

 

31-5/8

 

 

1

Filterscanberemoved

 

 

 

 

 

 

througheithersideof

 

 

 

 

 

 

 

 

theunit.

All dimensions are in inches. They are subject to change without notice. Certi- fied dimensions will be provided upon request.

2-3/16 1-1/4"KNOCKOUTFOR 5/8"ODLIQUIDCONNECTION*

*RefertoINSTALLINGREFRIGERANTMAINSininstalationinstruction whenpipingthroughtheoppositesideoftheunit.

FIGURE 3 - UNIT DIMENSIONS KEU180

ACCESSORIES

ELECTRIC HEATER - Add 14-1/4” to unit height when using 10, 16, 26, or 36 KW heater

SUPPLY AIR PLENUM - Add 27” to unit height when used.

BASE - Add 24” to unit height when used.

HOT WATER OR STEAM COIL - Add 6” to unit depth when used.

TABLE 20: UNIT CLEARANCES KEU180

MINIMUM CLEARANCES

180

Side Air with RETURN AIR opening

24”

Side with SUPPLY AIR opening1

24”

Side with PIPING CONNECTIONS2

61”

Side opposite PIPING CONNECTIONS3

26”

Bottom4

-

1.Overall dimension of the unit will vary if an electric heater, a supply air plenum or a base is used.

2.This dimension is required for removal of the DX coil. Only 26” is required for normal servicing.

3.If the coil has to be removed, this dimension is required to loosen screws that secure the coil to the unit frame. This dimension will also be required for blower motor access if the piping connections are made on the oppo- site side of the unit.

4.Allow enough clearance to trap the condensate drain lines.

18

Unitary Products Group

Page 18
Image 18
York K4EU090, K2EU060, K3EU120, K3EU180 manual UNIT DIMENSIONS KEU180 ACCESSORIES, UNIT CLEARANCES KEU180