TABLE 17: KEU PHYSICAL DATA

Component

Description

 

Model

 

 

 

 

 

060

090

120

180

 

 

 

 

 

 

 

 

EVAPORATOR

Centrifugal Blower (Dia. X Wd. in.)

15 X 15

15 X 15

15 X 15

18 X 18

BLOWER1

 

 

 

 

 

Fan Motor HP (Belt Drive)

3/4

1-1/2

2

3

 

Rows Deep

3

3

3

3

EVAPORATOR

Finned Length (in.)

30

46

46

54

COIL

Fins per Inch

13

13

13

13

 

Face Area (ft.2)

5.0

8.6

10.2

12.1

 

Rows Deep

2

2

2

2

 

Finned Length (in.)

30

46

46

54

HOT WATER COIL

Fins Per Inch

12

12

12

12

Face Area (ft.2)

3.8

5.4

5.4

9.0

 

 

Inlet Connection

1” NPTE

1” NPTE

1” NPTE

1-3/8” O.D

 

Outlet Connection

1” NPTE

1” NPTE

1” NPTE

1-3/8” O.D

 

Rows Deep

1

1

1

1

 

Finned Length (in.)

30

46

46

54

STEAM COIL

Fins Per Inch

8

8

8

8

Face Area (ft.2)

3.8

5.4

5.4

9.0

 

 

Inlet Connection

1-1/2” NPTE

1-1/2” NPTE

1-1/2” NPTE

1-1/2” NPTE

 

Outlet Connection

1-1/2” NPTE

1-1/2” NPTE

1-1/2” NPTE

1-1/2” NPTE

 

Quantity Per Unit (16” X 25” X 1”)

2

4

4

0

AIR FILTERS

Quantity Per Unit (20” X 20” X 1”)

0

0

0

6

 

Total Face Area (ft.2)

5.6

11.1

11.1

16.7

HOLDING CHARGE

Refrigerant 22 (lbs./oz.)

0/7

0/7

0/10

0/0