246653-YTG-E-0108

TABLE 39: FAN PERFORMANCE - 40 TON1,2

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IWG)

 

 

 

 

 

AIRFLOW (CFM)

 

0.2

0.4

 

 

0.6

 

0.8

 

1.0

 

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

8000

304

 

1.4

348

 

1.8

393

 

2.2

431

 

2.6

469

 

3.0

9000

329

 

1.9

371

 

2.3

411

 

2.7

448

 

3.2

484

 

3.7

10000

356

 

2.4

396

 

2.8

432

 

3.4

467

 

3.9

502

 

4.4

11000

385

 

3.0

421

 

3.6

454

 

4.1

488

 

4.7

519

 

5.3

12000

414

 

3.9

446

 

4.5

479

 

5.0

510

 

5.7

539

 

6.2

13000

442

 

4.8

473

 

5.5

504

 

6.1

532

 

6.7

560

 

7.4

14000

472

 

6.0

502

 

6.6

529

 

7.2

556

 

8.0

583

 

8.6

15000

503

 

7.2

529

 

8.0

555

 

8.6

581

 

9.3

607

 

10.1

16000

532

 

8.7

557

 

9.5

583

 

10.2

607

 

10.9

631

 

11.8

17000

562

 

10.4

587

 

11.1

611

 

12.0

633

 

12.7

656

 

13.5

18000

593

 

12.3

616

 

13.1

638

 

13.9

660

 

14.7

682

 

15.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IWG)

 

 

 

 

 

AIRFLOW (CFM)

 

1.2

1.4

 

 

1.6

 

1.8

 

2.0

 

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

8000

506

 

3.5

537

 

4.0

569

 

4.4

601

 

4.9

627

 

5.5

9000

518

 

4.2

549

 

4.6

581

 

5.1

610

 

5.8

637

 

6.3

10000

532

 

4.9

563

 

5.5

594

 

6.1

621

 

6.6

648

 

7.1

11000

549

 

5.8

579

 

6.4

608

 

7.0

634

 

7.6

661

 

8.2

12000

568

 

6.8

596

 

7.5

623

 

8.1

649

 

8.7

675

 

9.5

13000

588

 

8.0

614

 

8.6

640

 

9.3

665

 

10.0

690

 

10.7

14000

609

 

9.3

634

 

10.0

658

 

10.7

683

 

11.4

707

 

12.2

15000

631

 

10.8

655

 

11.6

679

 

12.3

702

 

13.1

724

 

13.9

16000

654

 

12.5

677

 

13.2

700

 

14.1

722

 

14.8

743

 

15.6

17000

678

 

14.3

701

 

15.1

722

 

16.0

742

 

16.8

763

 

17.6

18000

703

 

16.4

724

 

17.2

744

 

18.1

764

 

19.0

785

 

19.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IWG)

 

 

 

 

 

AIRFLOW (CFM)

 

2.2

2.4

 

 

2.6

 

2.8

 

3.0

 

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

8000

654

 

6.0

681

 

6.5

706

 

7.0

729

 

7.6

752

 

8.1

9000

664

 

6.8

691

 

7.4

715

 

8.0

738

 

8.5

761

 

9.1

10000

675

 

7.8

701

 

8.4

725

 

9.0

748

 

9.6

771

 

10.2

11000

687

 

8.8

712

 

9.5

735

 

10.2

758

 

10.8

781

 

11.4

12000

700

 

10.1

723

 

10.7

747

 

11.4

770

 

12.2

793

 

12.9

13000

714

 

11.4

737

 

12.2

760

 

12.9

782

 

13.7

805

 

14.4

14000

729

 

13.0

752

 

13.8

774

 

14.5

796

 

15.2

817

 

16.0

15000

746

 

14.6

768

 

15.4

790

 

16.2

811

 

17.0

831

 

17.9

16000

764

 

16.5

786

 

17.3

807

 

18.2

826

 

19.0

846

 

19.8

17000

784

 

18.5

805

 

19.4

824

 

20.3

843

 

21.1

863

 

22.1

18000

805

 

20.7

824

 

21.6

843

 

22.6

862

 

23.5

881

 

24.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AVAILABLE EXTERNAL STATIC PRESSURE (IWG)

 

 

 

 

 

AIRFLOW (CFM)

 

3.2

3.4

 

 

3.6

 

3.8

 

4.0

 

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

RPM

 

BHP3

8000

774

 

8.7

797

 

9.2

817

 

9.9

837

 

10.4

857

 

11.0

9000

784

 

9.8

806

 

10.3

826

 

10.9

846

 

11.6

866

 

12.2

10000

794

 

10.8

815

 

11.6

836

 

12.2

856

 

12.9

876

 

13.5

11000

804

 

12.2

824

 

12.8

845

 

13.5

865

 

14.3

886

 

14.9

12000

814

 

13.5

835

 

14.3

855

 

15.0

876

 

15.8

896

 

16.5

13000

825

 

15.1

846

 

15.9

866

 

16.6

886

 

17.4

906

 

18.2

14000

837

 

16.8

858

 

17.6

878

 

18.4

898

 

19.2

917

 

20.1

15000

851

 

18.7

871

 

19.5

891

 

20.4

910

 

21.2

928

 

22.1

16000

866

 

20.7

886

 

21.5

905

 

22.5

923

 

23.3

941

 

24.3

17000

882

 

23.0

901

 

23.8

919

 

24.8

937

 

25.7

-

 

-

18000

900

 

25.4

-

 

-

-

 

-

-

 

-

-

 

-

1.Fan performance is based on wet evaporator coils, clean 2” throwaway filters and system/cabinet effects at standard air density and 0 feet elevation.

2.Refer to Tables 12, 18, 23 and 42 for component additions and deductions to fan performance tables.

3.BHP includes drive losses.

4.Shaded RPMs require Class II blower.

50

Johnson Controls Unitary Products

Page 50
Image 50
York Y32, Y33, Y34 manual FAN Performance 40 TON1,2, 18000

Y32, Y34, Y33 specifications

The York Y33, Y32, and Y34 series represents a significant advancement in rooftop packaged units designed for commercial HVAC applications. These models are known for their reliability, energy efficiency, and innovative features that cater to diverse climate control needs.

The York Y33 series introduces modern features aimed at maximizing comfort and reducing energy costs. Its sleek design and compact size make it a versatile option for various applications, including retail spaces, office buildings, and industrial facilities. One of the standout features of the Y33 is its variable-speed compressor technology. This allows the unit to adjust its cooling output based on real-time demand, resulting in notable energy savings compared to traditional single-speed units.

The Y32 model builds upon the strengths of the Y33, offering enhanced capabilities for large commercial spaces. It incorporates advanced controls and building management system (BMS) connectivity, enabling seamless integration into existing infrastructure. The Y32 is designed with a focus on ease of maintenance and serviceability, featuring accessible components that streamline repair processes.

The York Y34 series emphasizes environmentally friendly practices, utilizing low-GWP refrigerants that minimizes its impact on the environment. It also boasts improved heat exchangers that increase efficiency and performance. The Y34’s design minimizes noise levels, making it ideal for applications where quiet operation is paramount, such as schools and healthcare facilities.

All three models share several key technologies, including fan and motor designs that optimize airflow while reducing energy consumption. Additionally, the series features enhanced insulation, significantly improving thermal performance and reducing the risk of condensation-related issues.

In summary, the York Y33, Y32, and Y34 models represent a commitment to innovation in commercial HVAC systems. Their combination of advanced technology, energy efficiency, and user-friendly design makes them suitable for a variety of applications while promoting sustainability and operational cost-effectiveness. Investing in these units not only supports optimal indoor climate control but also aligns with the growing demand for eco-friendly solutions in today’s commercial landscape.