COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION
CONDENSING UNIT MODEL NO. YHJF60S41S1 |
|
|
|
|
|
|
|
|
|
|
|
| ||||
INDOOR COIL MODEL NO. | AHX60 |
|
|
|
|
|
|
|
|
|
|
|
|
| ||
CONDENSING | IDCFM |
|
| 965 |
|
|
|
| 1165 |
|
|
|
| 1365 |
|
|
ENTERING AIR | ID DB (°F) | 80 | 80 | 75 | 80 | 80 | 80 | 80 | 75 | 80 | 80 | 80 | 80 | 75 | 80 | 80 |
TEMPERATURE |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
ID WB (°F) | 57 | 62 | 62 | 67 | 72 | 57 | 62 | 62 | 67 | 72 | 57 | 62 | 62 | 67 | 72 | |
| T.C. | 37.3 | 41.8 | 41.6 | 45.5 | 50.9 | 40.4 | 43.7 | 43.3 | 47.7 | 52.2 | 43.5 | 45.6 | 45.1 | 49.9 | 53.6 |
65 | S.C. | 35.2 | 32.0 | 27.8 | 27.8 | 23.7 | 38.1 | 35.1 | 30.0 | 30.0 | 24.9 | 41.1 | 38.2 | 32.2 | 32.3 | 26.1 |
| KW | 2.1 | 2.1 | 2.1 | 2.1 | 2.1 | 2.2 | 2.2 | 2.2 | 2.2 | 2.2 | 2.3 | 2.3 | 2.3 | 2.3 | 2.3 |
| T.C. | 36.2 | 39.9 | 39.8 | 43.6 | 48.4 | 39.0 | 41.6 | 41.3 | 45.5 | 49.8 | 41.8 | 43.3 | 42.8 | 47.4 | 51.2 |
75 | S.C. | 34.2 | 31.2 | 27.0 | 27.0 | 22.7 | 36.8 | 34.3 | 29.1 | 29.1 | 23.9 | 39.5 | 37.3 | 31.3 | 31.3 | 25.1 |
| KW | 2.4 | 2.4 | 2.4 | 2.4 | 2.4 | 2.5 | 2.5 | 2.5 | 2.5 | 2.5 | 2.6 | 2.6 | 2.6 | 2.6 | 2.6 |
| T.C. | 35.2 | 38.0 | 37.9 | 41.8 | 46.0 | 37.6 | 39.4 | 39.2 | 43.3 | 47.4 | 40.1 | 40.9 | 40.5 | 44.8 | 48.8 |
85 | S.C. | 33.2 | 30.5 | 26.1 | 26.1 | 21.7 | 35.5 | 33.5 | 28.3 | 28.3 | 22.9 | 37.8 | 36.5 | 30.4 | 30.4 | 24.0 |
| KW | 2.7 | 2.7 | 2.8 | 2.7 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.8 | 2.9 | 2.9 | 2.9 | 2.9 | 2.9 |
| T.C. | 34.1 | 36.0 | 36.0 | 39.9 | 43.6 | 36.2 | 37.3 | 37.1 | 41.1 | 45.0 | 38.3 | 38.5 | 38.2 | 42.3 | 46.5 |
95 | S.C. | 32.2 | 29.7 | 25.3 | 25.3 | 20.7 | 34.2 | 32.7 | 27.4 | 27.4 | 21.9 | 36.2 | 35.7 | 29.5 | 29.4 | 23.0 |
| KW | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.1 | 3.2 | 3.2 | 3.2 | 3.2 | 3.2 |
| T.C. | 32.4 | 33.7 | 33.7 | 37.3 | 40.9 | 34.2 | 34.7 | 34.6 | 38.3 | 42.1 | 36.1 | 35.7 | 35.5 | 39.3 | 43.3 |
105 | S.C. | 30.6 | 28.8 | 24.3 | 24.3 | 19.6 | 32.3 | 31.1 | 26.4 | 26.3 | 20.8 | 34.1 | 33.3 | 28.5 | 28.4 | 22.0 |
| KW | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.5 | 3.6 | 3.6 | 3.6 | 3.6 | 3.6 |
| T.C. | 30.6 | 31.4 | 31.4 | 34.7 | 38.3 | 32.3 | 32.1 | 32.1 | 35.5 | 39.2 | 33.9 | 32.8 | 32.8 | 36.3 | 40.1 |
115 | S.C. | 28.9 | 27.8 | 23.3 | 23.2 | 18.6 | 30.5 | 29.4 | 25.4 | 25.3 | 19.7 | 32.0 | 31.0 | 27.4 | 27.3 | 20.9 |
| KW | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 3.9 | 4.0 | 4.0 | 4.0 | 4.0 | 4.0 |
| T.C. | 28.9 | 29.1 | 29.1 | 32.1 | 35.7 | 30.3 | 29.5 | 29.6 | 32.7 | 36.3 | 31.7 | 29.9 | 30.1 | 33.4 | 37.0 |
125 | S.C. | 27.3 | 26.9 | 22.4 | 22.2 | 17.5 | 28.6 | 27.8 | 24.4 | 24.2 | 18.7 | 30.0 | 28.6 | 26.4 | 26.3 | 19.9 |
| KW | 4.3 | 4.3 | 4.3 | 4.3 | 4.3 | 4.3 | 4.3 | 4.3 | 4.3 | 4.4 | 4.4 | 4.4 | 4.4 | 4.4 | 4.4 |
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
NOTE: For dry bulb temperatures different than those listed (between
LOW CFM
Air Handler | Coil | T.C. | S.C. | KW |
MV20D | FC/MC62D | 1.00 | 1.00 | 0.99 |
Furnace | Coil | T.C. | S.C. | KW |
T*(8,L)X*C20 | FC/MC62D | 0.92 | 0.87 | 0.97 |
T*9X*C20 | FC/MC62D | 1.01 | 1.02 | 1.02 |
T*9X*D20 | FC/MC62D | 1.02 | 1.03 | 1.01 |
Y*(8,L)C*C20 | FC/MC62D | 0.97 | 0.94 | 0.99 |
(Y*9C/T*9V)*C20 | FC/MC62D | 0.97 | 0.95 | 1.00 |
(Y*9C/T*9V)*D20 | FC/MC62D | 0.98 | 0.96 | 1.01 |
18 | Johnson Controls Unitary Products |