COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION

CONDENSING UNIT MODEL NO. YHJF60S41S1

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

AHX60

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSING

IDCFM

 

 

1650

 

 

 

 

1850

 

 

 

 

2050

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

72

57

62

62

67

72

 

T.C.

56.5

60.0

59.6

65.6

70.6

58.5

61.2

60.8

66.7

72.5

60.5

62.3

62.0

67.8

74.4

65

S.C.

55.7

50.3

42.9

42.5

34.9

57.7

53.1

44.9

44.5

36.0

59.6

55.9

47.0

46.5

37.1

 

KW

3.4

3.5

3.5

3.5

3.6

3.5

3.6

3.5

3.6

3.7

3.6

3.6

3.6

3.7

3.8

 

T.C.

54.4

57.2

56.8

62.6

67.6

56.3

58.2

57.9

63.6

69.1

58.1

59.2

59.0

64.6

70.6

75

S.C.

53.6

49.1

41.6

41.3

33.5

55.4

51.9

43.7

43.2

34.6

57.3

54.7

45.7

45.2

35.7

 

KW

3.8

3.9

3.8

3.9

4.0

3.9

3.9

3.9

4.0

4.1

4.0

4.0

4.0

4.1

4.2

 

T.C.

52.3

54.4

54.0

59.6

64.6

54.0

55.2

55.0

60.5

65.8

55.7

56.1

56.0

61.3

66.9

85

S.C.

51.5

48.0

40.3

40.1

32.2

53.2

50.7

42.4

42.0

33.2

54.9

53.4

44.4

43.9

34.3

 

KW

4.2

4.2

4.2

4.3

4.4

4.3

4.3

4.3

4.4

4.5

4.4

4.4

4.4

4.5

4.6

 

T.C.

50.2

51.6

51.2

56.5

61.7

51.8

52.3

52.1

57.3

62.4

53.3

52.9

53.0

58.1

63.2

95

S.C.

49.5

46.8

39.1

38.9

30.8

51.0

49.5

41.1

40.8

31.8

52.5

52.1

43.1

42.6

32.9

 

KW

4.6

4.6

4.6

4.7

4.8

4.7

4.7

4.7

4.8

4.9

4.8

4.8

4.8

4.9

5.0

 

T.C.

47.5

48.0

47.8

52.6

57.5

48.8

49.0

48.4

53.3

58.1

50.2

50.0

49.1

54.0

58.8

105

S.C.

46.8

45.2

37.6

37.4

29.2

48.1

47.3

39.6

39.2

30.2

49.5

49.3

41.5

41.1

31.3

 

KW

5.1

5.1

5.1

5.2

5.3

5.2

5.2

5.2

5.3

5.4

5.3

5.3

5.3

5.4

5.5

 

T.C.

44.7

44.4

44.4

48.7

53.3

45.9

45.7

44.8

49.3

53.9

47.1

47.1

45.2

49.8

54.4

115

S.C.

44.1

43.7

36.1

35.8

27.6

45.2

45.0

38.0

37.7

28.6

46.4

46.4

39.9

39.5

29.7

 

KW

5.6

5.6

5.6

5.7

5.8

5.7

5.7

5.7

5.8

5.9

5.8

5.8

5.8

5.9

6.0

 

T.C.

42.0

40.7

41.0

44.8

49.2

43.0

42.5

41.1

45.3

49.6

44.0

44.2

41.3

45.7

50.0

125

S.C.

41.4

40.7

34.6

34.3

26.0

42.3

42.5

36.5

36.2

27.0

43.3

43.5

38.4

38.0

28.1

 

KW

6.1

6.1

6.1

6.2

6.3

6.2

6.2

6.2

6.3

6.4

6.3

6.3

6.3

6.4

6.5

NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

HIGH CFM

Air Handler

Coil

T.C.

S.C.

KW

MV20D

FC/MC62D

1.03

1.01

0.96

Furnace

Coil

T.C.

S.C.

KW

T*(8,L)X*C20

FC/MC62D

1.02

0.97

0.93

T*9X*C20

FC/MC62D

1.01

0.95

0.93

T*9X*D20

FC/MC62D

1.02

0.97

0.93

Y*(8,L)C*C20

FC/MC62D

1.01

0.96

0.93

(Y*9C/T*9V)*C20

FC/MC62D

1.01

0.96

0.96

(Y*9C/T*9V)*D20

FC/MC62D

1.01

0.96

0.95

Johnson Controls Unitary Products

19

Page 19
Image 19
York YHJF18 THRU 60 warranty High Cfm, YTG-B-0509, CONDENSING UNIT MODEL NO. YHJF60S41S1, Indoor Coil Model No, AHX60