York YHJF18 THRU 60 YHJF24S41S1, Heating Performance Data, Condensing Unit Model No, AHX30

Models: YHJF18 THRU 60

1 26
Download 26 pages 40.72 Kb
Page 21
Image 21
YHJF24S41S1

 

 

 

 

 

 

 

 

 

510667-YTG-B-0509

 

 

 

 

 

 

 

 

 

 

HEATING PERFORMANCE DATA

 

 

 

 

 

 

 

 

 

CONDENSING UNIT MODEL NO

YHJF24S41S1

 

 

 

 

 

 

 

EVAPORATOR COIL MODEL NO

AHX30

 

 

 

 

 

 

 

 

AIR TEMP.

AIR TEMP.

 

 

 

 

ID CFM

 

 

 

 

ENTERING

ENTERING

 

600

 

 

800

 

 

1000

 

OUTDOOR UNIT

INDOOR COIL

 

 

 

 

 

 

 

 

 

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

MBTUH

KW

C.O.P.

 

 

 

 

 

 

 

 

 

 

 

 

60

26.8

4.0

1.7

27.6

4.3

1.6

28.4

4.5

1.5

60

 

 

 

 

 

 

 

 

 

 

70

25.1

3.4

1.9

26.1

3.7

1.8

27.2

4.0

1.6

 

 

 

 

 

 

 

 

 

 

 

 

80

23.3

2.9

2.1

24.7

3.2

2.0

26.1

3.5

1.8

 

 

 

 

 

 

 

 

 

 

 

 

60

24.8

3.8

1.7

25.0

4.0

1.5

25.2

4.1

1.4

47

 

 

 

 

 

 

 

 

 

 

70

22.7

3.2

1.8

23.2

3.4

1.7

23.7

3.6

1.6

 

 

 

 

 

 

 

 

 

 

 

 

80

20.7

2.7

2.0

21.5

2.9

1.9

22.2

3.1

1.8

 

 

 

 

 

 

 

 

 

 

 

 

60

20.8

3.3

1.6

21.5

3.5

1.5

22.3

3.7

1.4

40

 

 

 

 

 

 

 

 

 

 

70

19.5

2.9

1.8

20.3

3.0

1.7

21.2

3.2

1.6

 

 

 

 

 

 

 

 

 

 

 

 

80

18.2

2.4

2.0

19.1

2.6

1.8

20.0

2.8

1.7

 

 

 

 

 

 

 

 

 

 

 

 

60

18.7

3.1

1.6

18.8

3.1

1.5

18.9

3.2

1.4

30

 

 

 

 

 

 

 

 

 

 

70

17.5

2.6

1.7

17.8

2.7

1.6

18.1

2.8

1.5

 

 

 

 

 

 

 

 

 

 

 

 

80

16.2

2.3

1.9

16.8

2.4

1.8

17.3

2.5

1.7

 

 

 

 

 

 

 

 

 

 

 

 

60

15.5

2.7

1.5

15.8

2.7

1.4

16.2

2.8

1.4

17

 

 

 

 

 

 

 

 

 

 

70

13.1

2.1

1.6

13.8

2.2

1.6

14.5

2.3

1.5

 

 

 

 

 

 

 

 

 

 

 

 

80

10.8

1.6

1.8

11.8

1.7

1.7

12.8

1.9

1.6

 

 

 

 

 

 

 

 

 

 

 

 

60

13.5

2.4

1.5

13.8

2.4

1.4

14.0

2.4

1.3

10

 

 

 

 

 

 

 

 

 

 

70

12.2

1.9

1.6

12.5

2.0

1.5

12.8

2.0

1.5

 

 

 

 

 

 

 

 

 

 

 

 

80

10.8

1.6

1.8

11.2

1.7

1.7

11.6

1.7

1.6

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

Air Handler

Coil

MBH

KW

COP

AHX36

1.01

1.02

0.99

AV*36

0.99

1.02

0.97

F6FP030

1.00

1.00

1.00

F6FP036

1.00

1.01

0.99

MV12B

FC/MC35B

1.00

1.01

0.99

MV12B

FC/MC43B

1.00

1.05

0.95

Furnace

Coil

MBH

KW

COP

T*(8,L)X*A12

FC/MC/PC32A

0.99

1.02

0.97

T*(8,L)X*B12

FC/MC/PC35B

0.99

1.03

0.96

T*(8,L)X*C16

FC/MC/PC35C

0.99

1.03

0.96

T*(8,L)X*C20

FC/MC/PC35C

0.99

1.03

0.96

T*9X*B12

FC/MC/PC35B

0.99

1.02

0.97

T*9X*C16

FC/MC/PC35C

0.99

1.04

0.95

T*9X*C20

FC/MC/PC35C

1.00

1.02

0.98

T*(8,L)X*A12

FC/MC/PC37A

1.00

1.07

0.94

T*(8,L)X*B12

FC/MC/PC43B

0.99

1.07

0.93

Furnace

Coil

MBH

KW

COP

T*(8,L)X*C16

FC/MC/PC43C

0.99

1.07

0.93

T*9X*B12

FC/MC/PC43B

1.00

1.07

0.94

T*9X*C16

FC/MC/PC43C

0.99

1.04

0.95

T*9X*C20

FC/MC/PC43C

0.99

1.03

0.96

Y*(8,L)C*A12

FC/MC/PC32A

1.00

0.99

1.01

Y*(8,L)C*B12

FC/MC/PC35B

0.99

0.98

1.01

Y*(8,L)C*C16

FC/MC/PC35C

1.00

1.01

0.99

Y*(8,L)C*C20

FC/MC/PC35C

0.98

0.99

0.99

(Y*9C/T*9V)*B12

FC/MC/PC35B

1.00

1.00

1.00

(Y*9C/T*9V)*C16

FC/MC/PC35C

1.00

1.02

0.98

(Y*9C/T*9V)*C20

FC/MC/PC35C

0.99

0.98

1.01

Y*(8,L)C*A12

FC/MC/PC37A

1.01

1.03

0.98

Y*(8,L)C*B12

FC/MC/PC43B

0.99

1.01

0.98

Y*(8,L)C*C16

FC/MC/PC43C

1.00

1.05

0.95

Y*(8,L)C*C20

FC/MC/PC43C

0.99

1.02

0.97

(Y*9C/T*9V)*B12

FC/MC/PC43B

1.00

1.04

0.96

(Y*9C/T*9V)*C16

FC/MC/PC43C

1.00

1.05

0.95

(Y*9C/T*9V)*C20

FC/MC/PC43C

1.01

1.05

0.96

Johnson Controls Unitary Products

21

Page 21
Image 21
York YHJF18 THRU 60 YHJF24S41S1, Heating Performance Data, Condensing Unit Model No, Evaporator Coil Model No, AHX30