COOLING CAPACITY - With Air Handler Coils

510667-YTG-B-0509

COOLING CAPACITY - With Air Handler Coils

UNIT

AIR HANDLER

 

 

COIL

 

 

 

 

COOLING

 

 

MODEL

MODEL

 

W

 

MODEL1

STAGE

RATED

 

NET MBH

SEER

EER

 

 

 

CFM

 

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.5 SEER HP WITH

MV - VARIABLE SPEED

 

 

 

 

YHJF18S41S1

MV12B

 

17

 

FC/MC35B

600

 

18.0

13.0

15.00

12.50

MV12B

 

17

 

FC/MC43B

600

 

18.0

13.3

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF24S41S1

MV12B

 

17

 

FC/MC35B

800

 

22.8

17.2

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

MV12B

 

17

 

FC/MC43B

800

 

23.4

18.0

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF30S41S1

MV12B

 

17

 

FC/MC43B

1000

 

29.0

21.6

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

MV16C

 

21

 

FC/MC43C

1000

 

29.0

21.6

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF36S41S1

MV12B

 

17

 

FC/MC43B

1225

 

35.4

26.6

14.35

12.00

 

 

 

 

 

 

 

 

 

 

 

 

MV16C

 

21

 

FC/MC43C

1200

 

35.2

26.4

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF42S41S1

MV20D

 

24

 

FC/MC62D

1400

 

40.0

30.8

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF48S41S1

MV20D

 

24

 

FC/MC62D

1630

 

48.0

36.2

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF60S41S1

MV20D

 

24

 

FC/MC62D

1

1160

 

48.0

31.0

14.50

12.00

 

 

 

 

 

 

 

 

 

2

1855

 

57.0

40.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14.5

SEER HP WITH AV /

SV / F*FV

- VARIABLE

SPEED

 

 

 

YHJF18S41S1

AV*36

 

21

 

630

 

18.0

13.3

15.00

12.50

YHJF24S41S1

AV*36

 

21

 

725

 

22.8

16.8

15.00

12.50

YHJF30S41S1

AV*36

 

21

 

960

 

29.2

21.8

15.00

12.50

YHJF36S41S1

AV*36

 

21

 

1190

 

35.4

26.4

14.50

12.00

 

 

 

 

 

14.5 SEER HP WITH

AHP / SHP / AHX / F*FP

 

 

 

 

YHJF18S41S1

AHX30

 

17

 

640

 

18.0

13.3

15.00

12.50

 

AHX30

 

17

 

800

 

22.8

17.1

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF24S41S1

F6FP030

 

17

 

850

 

22.8

17.3

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP036

 

21

 

855

 

22.8

17.4

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AHX36

 

21

 

820

 

23.0

17.4

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF30S41S1

AHX36

 

21

 

1030

 

29.4

22.2

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

21

 

1065

 

29.4

22.2

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AHX36

 

21

 

1210

 

35.4

26.6

14.50

12.00

YHJF36S41S1

 

 

 

 

 

 

 

 

 

 

 

 

AHX42

 

21

 

1190

 

35.8

26.8

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

F6FP042

 

24

 

1290

 

36.0

27.6

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF42S41S1

AHX60

 

24

 

1355

 

40.0

30.2

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

F6FP060

 

24

 

1475

 

40.5

31.4

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF48S41S1

AHX60

 

24

 

1570

 

48.0

35.6

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

F6FP060

 

24

 

1570

 

48.0

35.6

15.00

12.50

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YHJF60S41S1

AHX60

 

24

 

1

1160

 

47.5

30.5

14.50

12.00

 

 

 

 

 

 

 

 

 

 

2

1855

 

57.0

40.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rated in accordance with DOE test procedures (Federal Register 12-27-79 and 3-18-88) and ARI Standards 210. Cooling MBH based on 80°F entering air temperature, 50% RH, and rated air flow.

EER (Energy Efficiency Ratio) is the total cooling output in BTU’s at 95°F outdoor ambient divided by the total electric power in watt-hours at those conditions. SEER (Seasonal Energy Efficiency Ratio) is the total cooling output in BTU’s during a normal annual usage period for cooling divided by the total electric power input in watt-hours during the same period.

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

— = Not applicable.