510667-YTG-B-0509

COOLING CAPACITY - With High Efficiency Motor Furnaces (Continued)

UNIT

FURNACE

COIL

 

 

 

 

COOLING

 

 

MODEL

MODEL

MODEL1

W

STAGE

RATED

Net MBH

SEER

EER

 

 

CFM

TOTAL

SENS.

 

 

 

 

 

 

 

 

 

14.5 SEER HP WITH VARIABLE SPEED FURNACES2

 

 

 

 

T*(8,L)X*A12

FC/MC/PC37A

14

1290

35.8

27.4

14.50

12.00

 

T*(8,L)X*B12

FC/MC/PC43B

17

1300

35.8

27.4

14.50

12.00

 

T*(8,L)X*C16

FC/MC/PC43C

21

1175

35.4

26.4

15.00

12.50

 

T*(8,L)X*C20

FC/MC/PC43C

21

1250

36.0

27.4

15.00

12.50

 

T*9X*B12

FC/MC/PC43B

17

1270

35.8

27.4

14.50

12.00

YHJF36S41S1

T*9X*C16

FC/MC/PC43C

21

1260

36.0

27.4

14.50

12.00

 

T*9X*C20

FC/MC/PC43C

21

1185

35.2

26.4

14.50

12.00

 

Y*(8,L)C*C16

FC/MC/PC43C

21

1205

35.2

26.4

14.50

12.00

 

Y*(8,L)C*C20

FC/MC/PC43C

21

1190

35.2

26.4

14.50

12.00

 

(Y*9C/T*9V)*C16

FC/MC/PC43C

21

1240

35.6

27.2

14.20

12.00

 

(Y*9C/T*9V)*C20

FC/MC/PC43C

21

1200

35.2

26.4

14.35

12.00

 

T*(8,L)X*C16

FC/MC62D

21

1360

40.5

31.0

15.00

12.50

 

T*(8,L)X*C20

FC/MC62D

21

1485

40.5

31.8

15.00

12.50

 

T*9X*C16

FC/MC62D

21

1460

40.0

30.8

14.50

12.00

 

T*9X*C20

FC/MC62D

21

1460

40.5

31.0

14.50

12.00

YHJF42S41S1

T*9X*D20

FC/MC62D

24

1425

40.5

31.0

14.50

12.00

 

Y*(8,L)C*C16

FC/MC62D

21

1420

40.0

30.8

14.40

12.00

 

Y*(8,L)C*C20

FC/MC62D

21

1410

40.5

30.8

14.50

12.00

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1445

40.0

30.6

14.05

11.90

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1455

40.0

30.6

14.25

12.00

 

T*(8,L)X*C16

FC/MC62D

21

1610

48.0

36.2

14.50

12.00

 

T*(8,L)X*C20

FC/MC62D

21

1665

48.0

36.2

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

T*9X*C16

FC/MC62D

21

1550

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

T*9X*C20

FC/MC62D

21

1595

48.0

36.2

14.50

12.00

 

 

 

 

 

 

 

 

 

 

YHJF48S41S1

T*9X*D20

FC/MC62D

24

1610

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C16

FC/MC62D

21

1635

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C20

FC/MC62D

21

1615

48.0

36.0

14.50

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C16

FC/MC62D

21

1590

47.5

36.0

14.35

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1655

47.5

35.8

14.05

12.00

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1630

47.5

35.8

14.25

12.00

 

T*(8,L)X*C20

FC/MC62D

21

1

835

44.0

27.0

14.50

12.00

 

2

1665

57.0

39.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T*9X*C20

FC/MC62D

21

1

1220

48.5

31.6

14.50

12.00

 

 

 

 

 

 

2

1595

56.5

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T*9X*D20

FC/MC62D

24

1

1240

48.5

31.8

14.50

12.00

 

 

 

 

 

YHJF60S41S1

2

1645

56.5

39.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Y*(8,L)C*C20

FC/MC62D

21

1

1015

46.0

29.2

14.50

12.00

 

 

 

 

 

 

 

2

1615

56.5

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*C20

FC/MC62D

21

1

1040

46.5

29.4

14.50

12.00

 

 

 

 

 

 

2

1655

56.0

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Y*9C/T*9V)*D20

FC/MC62D

24

1

1085

47.0

29.8

14.50

12.00

 

 

 

 

 

 

2

1630

56.0

38.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.MC coils available with a factory installed horizontal drain pan. See price pages for specific model number.

2.Variable speed furnaces have B.O.D (Blower on Delay) standard.

6

Johnson Controls Unitary Products

Page 6
Image 6
York YHJF18 THRU 60 warranty Unit Furnace, Cooling Model MODEL1 Stage Rated, Seer EER CFM