271457-YTG-B-0908

HEATING CAPACITY - YZB03011With Variable Speed Furnaces (Continued)

VARIABLE

COIL1

 

 

 

ARI HEATING2

 

 

 

SPEED

 

 

 

 

 

 

 

 

 

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

 

 

 

G*9V*A12

HD36

28.8

3.02

2.79

 

18.0

 

1.92

2.75

7.80

G*9V*B12

HD36

28.6

3.06

2.74

 

17.9

 

1.94

2.70

7.90

G*9V*C16

HD36

28.6

3.08

2.72

 

17.8

 

1.96

2.66

7.90

G*9V*C20

HD36

28.6

3.06

2.74

 

17.9

 

1.94

2.70

7.90

G*9V*A12

UC30A

29.6

3.54

2.45

 

18.3

 

2.34

2.29

8.10

G*9V*A12

UC36A

29.6

3.54

2.45

 

18.3

 

2.36

2.27

8.10

G*9V*B12

UC36B

29.4

3.54

2.43

 

16.7

 

2.14

2.29

8.10

G*9V*C16

UC36C

29.4

3.58

2.41

 

17.3

 

2.30

2.20

8.20

G*9V*C20

UC36C

29.4

3.56

2.42

 

17.3

 

2.28

2.22

8.20

1.Rated CFM same as for cooling.

2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.

CP equals MBH output divided by (total KW input x 3.412).

HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.

HEATING CAPACITY - YZB03611With Variable Speed Furnaces

VARIABLE

COIL1

 

 

 

ARI HEATING2

 

 

 

SPEED

 

 

 

 

 

 

 

 

 

MODEL

 

47°F

 

 

 

 

17°F

 

HSPF

FURNACE

 

 

 

 

 

 

 

 

 

 

MBH

COP

KW

 

MBH

 

COP

KW

STD

 

 

 

 

 

1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES

 

 

 

PV8*A12

FC/MC/PC36A

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

PV9*A12

FC/MC/PC36A

36.0

3.42

3.08

24.0

 

2.36

2.98

8.35

PV8*B16

FC/MC/PC36B

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

P(C,V)9*B12

FC/MC/PC36B

36.0

3.42

3.08

24.0

 

2.36

2.98

8.35

PV8*C16

FC/MC/PC36C

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

PV8*C20

FC/MC/PC36C

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

P(C,V)9*C16

FC/MC/PC36C

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

P(C,V)9*C20

FC/MC/PC36C

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

PV8*B16

HC36

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

P(C,V)9*B12

HC36

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

PV8*B16

HD36

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

P(C,V)9*B12

HD36

36.0

3.36

3.14

24.4

 

2.32

3.08

8.00

Y*(8,L)C*B12

FC/MC/PC35B

35.6

3.30

3.16

24.6

 

2.32

3.11

8.00

Y*9C*B12

FC/MC/PC35B

35.4

3.30

3.14

24.0

 

2.30

3.06

8.00

Y*(8,L)C*C16

FC/MC/PC35C

35.4

3.40

3.05

24.2

 

2.38

2.98

8.10

Y*(8,L)C*C20

FC/MC/PC35C

35.2

3.42

3.02

24.2

 

2.40

2.96

8.10

Y*9C*C16

FC/MC/PC35C

35.4

3.38

3.07

24.4

 

2.36

3.03

8.10

Y*9C*C20

FC/MC/PC35C

35.8

3.38

3.10

23.8

 

2.30

3.03

8.10

Y*(8,L)C*A12

FC/MC/PC36A

35.6

3.28

3.18

24.6

 

2.32

3.11

8.00

Y*(8,L)C*B12

FC/MC/PC36B

35.4

3.32

3.13

24.4

 

2.34

3.06

8.00

Y*9C*B12

FC/MC/PC36B

35.4

3.34

3.11

24.4

 

2.36

3.03

8.00

Y*(8,L)C*C16

FC/MC/PC36C

35.2

3.40

3.03

24.4

 

2.38

3.00

8.10

Y*(8,L)C*C20

FC/MC/PC36C

35.2

3.42

3.02

24.4

 

2.40

2.98

8.10

Y*9C*C16

FC/MC/PC36C

35.2

3.42

3.02

24.4

 

2.40

2.98

8.10

Y*9C*C20

FC/MC/PC36C

35.6

3.42

3.05

23.6

 

2.32

2.98

8.10

Y*(8,L)C*A12

FC/MC/PC37A

35.0

3.26

3.15

24.2

 

2.34

3.03

8.00

Y*(8,L)C*B12

FC/MC/PC43B

35.8

3.42

3.07

24.2

 

2.36

3.01

8.10

Y*9C*B12

FC/MC/PC43B

35.8

3.42

3.07

24.2

 

2.36

3.01

8.10

Y*(8,L)C*C16

FC/MC/PC43C

35.4

3.52

2.95

23.8

 

2.42

2.88

8.20

Y*(8,L)C*C20

FC/MC/PC43C

35.4

3.52

2.95

23.8

 

2.42

2.88

8.20

Y*9C*C16

FC/MC/PC43C

35.6

3.46

3.02

24.0

 

2.38

2.96

8.10

Y*9C*C20

FC/MC/PC43C

35.4

3.50

2.96

24.0

 

2.42

2.91

8.20

Y*(8,L)C*C16

FC/MC/PC48C

35.4

3.54

2.93

23.8

 

2.44

2.86

8.20

For Notes See Page 19.

18

Johnson Controls Unitary Products

Page 18
Image 18
York YZB018 THRU 060 warranty Heating Capacity YZB03611With Variable Speed Furnaces, Furnace MBH COP STD

YZB018 THRU 060 specifications

The York YZB018 THRU 060 series represents a cutting-edge solution for commercial heating and cooling needs, designed to provide efficient and reliable performance in a variety of applications. These units encompass a range of capacities from 1.5 to 5 tons, making them suitable for different building sizes and requirements. The YZB series is well-known for its robust construction, advanced technology, and exceptional energy efficiency.

One of the main features of the York YZB series is its high-efficiency scroll compressors. These compressors are engineered to deliver superior performance while minimizing energy consumption, thus reducing operational costs for end-users. In addition, the use of environmentally friendly refrigerants helps to comply with modern regulations regarding greenhouse gas emissions, making the YZB series a sustainable choice for businesses.

The YZB series incorporates a user-friendly control system, allowing for simple adjustments to temperature settings and operational modes. This feature enhances user experience and enables better management of indoor climate conditions. The units also come equipped with advanced diagnostic capabilities, which help in identifying potential issues early and optimizing maintenance schedules. This proactive approach extends the lifespan of the equipment while ensuring reliable operation.

Durability is a hallmark of the York YZB series. Constructed with high-quality materials, these units can withstand the rigors of commercial use, including exposure to varying weather conditions. The corrosion-resistant cabinet and robust internal components ensure longevity and performance over time.

Another important characteristic of the YZB series is its quiet operation. With noise levels minimized, these systems are ideal for installations requiring low sound emissions, such as offices, schools, and healthcare facilities.

The flexibility of the YZB series is also noteworthy. The units can be configured for different applications, including rooftop installations, split systems, or even for use in conjunction with ductless systems. This adaptability makes them a versatile option for a wide array of commercial applications.

In summary, the York YZB018 THRU 060 series is distinguished by its energy-efficient performance, robust construction, and advanced technological features. With its user-friendly controls, diagnostic capabilities, and quiet operation, this series is an exemplary choice for businesses aiming for optimal climate management and sustainability in their operations.