HEATING PERFORMANCE DATA
OUTDOOR UNIT MODEL NO. | YZB06012 |
|
|
|
|
|
|
|
| ||
INDOOR COIL MODEL NO. | FC/MC62D |
|
|
|
|
|
|
|
| ||
AIR TEMP. | AIR TEMP. |
|
|
|
|
| ID CFM |
|
|
|
|
ENTERING | ENTERING |
|
| 1650 |
|
| 1900 |
|
| 2150 |
|
OUTDOOR UNIT | INDOOR COIL |
|
|
|
|
|
|
|
|
|
|
MBTUH |
| KW | C.O.P. | MBTUH | KW | C.O.P. | MBTUH | KW | C.O.P. | ||
| 60 | 71.5 |
| 4.9 | 4.3 | 72.1 | 4.8 | 4.4 | 72.7 | 4.6 | 4.6 |
60 |
|
|
|
|
|
|
|
|
|
|
|
70 | 70.3 |
| 5.4 | 3.8 | 70.9 | 5.3 | 3.9 | 71.5 | 5.1 | 4.1 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 69.2 |
| 5.9 | 3.4 | 69.8 | 5.8 | 3.5 | 70.3 | 5.6 | 3.7 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 61.1 |
| 4.8 | 3.8 | 61.2 | 4.7 | 3.8 | 61.4 | 4.6 | 3.9 |
47 |
|
|
|
|
|
|
|
|
|
|
|
70 | 60.3 |
| 5.3 | 3.4 | 60.6 | 5.2 | 3.4 | 60.8 | 5.1 | 3.5 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 59.6 |
| 5.8 | 3.0 | 59.9 | 5.7 | 3.1 | 60.2 | 5.6 | 3.2 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 53.5 |
| 4.7 | 3.3 | 50.2 | 4.6 | 3.2 | 47.0 | 4.6 | 3.0 |
40 |
|
|
|
|
|
|
|
|
|
|
|
70 | 53.7 |
| 5.3 | 3.0 | 52.0 | 5.1 | 3.0 | 50.4 | 5.0 | 3.0 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 53.9 |
| 5.9 | 2.7 | 53.8 | 5.6 | 2.8 | 53.8 | 5.4 | 2.9 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 43.9 |
| 4.6 | 2.8 | 42.5 | 4.5 | 2.8 | 41.1 | 4.5 | 2.7 |
30 |
|
|
|
|
|
|
|
|
|
|
|
70 | 44.0 |
| 5.2 | 2.5 | 42.6 | 5.1 | 2.4 | 41.1 | 5.1 | 2.4 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 44.2 |
| 5.8 | 2.2 | 42.7 | 5.7 | 2.2 | 41.2 | 5.6 | 2.1 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 35.4 |
| 4.4 | 2.4 | 35.0 | 4.3 | 2.4 | 34.6 | 4.3 | 2.4 |
17 |
|
|
|
|
|
|
|
|
|
|
|
70 | 35.0 |
| 4.9 | 2.1 | 35.3 | 4.9 | 2.1 | 35.7 | 4.8 | 2.2 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 34.5 |
| 5.4 | 1.9 | 35.7 | 5.4 | 1.9 | 36.8 | 5.4 | 2.0 |
|
|
|
|
|
|
|
|
|
|
|
|
| 60 | 30.7 |
| 4.4 | 2.1 | 28.9 | 4.3 | 2.0 | 27.2 | 4.3 | 1.9 |
10 |
|
|
|
|
|
|
|
|
|
|
|
70 | 30.9 |
| 4.9 | 1.8 | 30.0 | 4.9 | 1.8 | 29.1 | 4.9 | 1.8 | |
|
|
|
|
|
|
|
|
|
|
|
|
| 80 | 31.1 |
| 5.5 | 1.7 | 31.0 | 5.4 | 1.7 | 31.0 | 5.4 | 1.7 |
|
|
|
|
|
|
|
|
|
|
|
|
NOTE: ALL CAPACITIES INCLUDE INDOOR FAN HEAT AT 1250 BTUH/1000 CFM.
Multipliers for determining the performance with other indoor sections.
Air Handler | Coil |
| MBH | KW | COP |
MV20D |
| FC/MC62D | 1.00 | 1.01 | 0.99 |
MA20D |
| FC/MC62D | 1.00 | 1.00 | 1.00 |
Variable Speed | Coil | MBH | KW | COP | |
Furnace | |||||
|
|
|
| ||
P(C,V)9*D20 | FC/MC62D | 0.96 | 1.01 | 0.99 | |
Y*(8,L)C*C20 | FC/MC62D | 0.98 | 1.00 | 0.98 | |
Y*9C*C20 | FC/MC62D | 0.99 | 0.99 | 1.00 | |
Y*9C*D20 | FC/MC62D | 0.99 | 0.99 | 1.00 | |
G*9V*C20 | FC/MC62D | 0.99 | 0.99 | 1.00 | |
G*9V*D20 | FC/MC62D | 0.99 | 0.99 | 1.00 |
Subject to change without notice. Printed in U.S.A. | |
Copyright © 2008 by Johnson Controls, Inc. All rights reserved. | Supersedes: |
Johnson Controls Unitary Products
5005 York Drive