HEATING CAPACITY - YZB04211With Variable Speed Furnaces
VARIABLE | COIL1 |
|
|
| ARI HEATING2 |
|
|
| ||
SPEED |
|
|
|
|
|
|
|
|
| |
MODEL |
| 47°F |
|
|
|
| 17°F |
| HSPF | |
FURNACE |
|
|
|
|
|
|
|
|
| |
| MBH | COP | KW |
| MBH |
| COP | KW | STD | |
|
|
|
| |||||||
| 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES |
|
|
| ||||||
PV8*C16 | FC/MC/PC48C | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
PV8*C20 | FC/MC/PC48C | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
P(C,V)9*C16 | FC/MC/PC48C | 42.0 | 3.74 | 3.29 |
| 28.0 |
| 2.58 | 3.18 | 8.60 |
P(C,V)9*C20 | FC/MC/PC48C | 42.0 | 3.76 | 3.27 |
| 28.0 |
| 2.60 | 3.16 | 8.60 |
P(C,V)9*D20 | FC/MC/PC48D | 42.0 | 3.74 | 3.29 |
| 28.0 |
| 2.58 | 3.18 | 8.60 |
PV8*C20 | HC48 | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
P(C,V)9*C20 | HC48 | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
PV8*C20 | HD48 | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
P(C,V)9*C20 | HD48 | 42.0 | 3.66 | 3.36 |
| 28.4 |
| 2.54 | 3.28 | 8.00 |
Y*(8,L)C*C16 | FC/MC/PC48C | 41.5 | 3.80 | 3.20 |
| 28.0 |
| 2.62 | 3.13 | 8.10 |
Y*(8,L)C*C20 | FC/MC/PC48C | 41.5 | 3.82 | 3.18 |
| 27.8 |
| 2.64 | 3.09 | 8.20 |
Y*9C*C16 | FC/MC/PC48C | 41.5 | 3.78 | 3.22 |
| 28.0 |
| 2.60 | 3.16 | 8.10 |
Y*9C*C20 | FC/MC/PC48C | 42.0 | 3.76 | 3.27 |
| 28.2 |
| 2.60 | 3.18 | 8.10 |
Y*9C*D20 | FC/MC/PC48D | 41.5 | 3.78 | 3.22 |
| 28.0 |
| 2.62 | 3.13 | 8.10 |
Y*(8,L)C*B12 | HD48 | 41.0 | 3.32 | 3.62 |
| 27.2 |
| 2.30 | 3.47 | 7.80 |
Y*(8,L)C*C16 | HD48 | 41.0 | 3.46 | 3.47 |
| 27.0 |
| 2.36 | 3.35 | 7.90 |
Y*(8,L)C*C20 | HD48 | 40.5 | 3.48 | 3.41 |
| 26.8 |
| 2.36 | 3.33 | 7.90 |
Y*9C*B12 | HD48 | 40.0 | 3.16 | 3.71 |
| 27.0 |
| 2.24 | 3.53 | 7.80 |
Y*9C*C16 | HD48 | 41.0 | 3.40 | 3.53 |
| 27.6 |
| 2.32 | 3.49 | 7.90 |
Y*9C*C20 | HD48 | 41.0 | 3.38 | 3.56 |
| 27.6 |
| 2.32 | 3.49 | 7.90 |
Y*9C*D20 | HD48 | 41.0 | 3.44 | 3.49 |
| 27.0 |
| 2.34 | 3.38 | 7.90 |
Y*(8,L)C*C16 | UC48C | 42.0 | 3.90 | 3.16 |
| 28.0 |
| 2.68 | 3.06 | 8.20 |
Y*(8,L)C*C20 | UC48C | 42.0 | 3.94 | 3.12 |
| 28.0 |
| 2.70 | 3.04 | 8.20 |
Y*9C*C16 | UC48C | 42.0 | 3.88 | 3.17 |
| 28.2 |
| 2.66 | 3.11 | 8.20 |
Y*9C*C20 | UC48C | 42.0 | 3.86 | 3.19 |
| 28.2 |
| 2.64 | 3.13 | 8.20 |
Y*9C*D20 | UC48D | 42.0 | 3.90 | 3.16 |
| 28.0 |
| 2.66 | 3.09 | 8.20 |
G*9V*C16 | FC/MC/PC48C | 41.5 | 3.78 | 3.22 |
| 28.0 |
| 2.60 | 3.16 | 8.10 |
G*9V*C20 | FC/MC/PC48C | 42.0 | 3.76 | 3.27 |
| 28.2 |
| 2.60 | 3.18 | 8.10 |
G*9V*D20 | FC/MC/PC48D | 41.5 | 3.78 | 3.22 |
| 28.0 |
| 2.62 | 3.13 | 8.10 |
G*9V*B12 | HD48 | 40.0 | 3.16 | 3.71 |
| 27.0 |
| 2.24 | 3.53 | 7.80 |
G*9V*C16 | HD48 | 41.0 | 3.40 | 3.53 |
| 27.6 |
| 2.32 | 3.49 | 7.90 |
G*9V*C20 | HD48 | 41.0 | 3.38 | 3.56 |
| 27.6 |
| 2.32 | 3.49 | 7.90 |
G*9V*D20 | HD48 | 41.0 | 3.44 | 3.49 |
| 27.0 |
| 2.34 | 3.38 | 7.90 |
G*9V*C16 | UC48C | 42.0 | 3.88 | 3.17 |
| 28.2 |
| 2.66 | 3.11 | 8.20 |
G*9V*C20 | UC48C | 42.0 | 3.86 | 3.19 |
| 28.2 |
| 2.64 | 3.13 | 8.20 |
G*9V*D20 | UC48D | 42.0 | 3.90 | 3.16 |
| 28.0 |
| 2.66 | 3.09 | 8.20 |
1.Rated CFM same as for cooling.
2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
20 | Johnson Controls Unitary Products |