COOLING PERFORMANCE DATA

OUTDOOR UNIT MODEL NO.

YZB04811

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INDOOR COIL MODEL NO.

FC/MC/PC/UC60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONDENSER

ID CFM

 

 

1400

 

 

 

 

1600

 

 

 

 

1800

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENTERING AIR

ID DB (°F)

80

80

75

80

80

80

80

75

80

80

80

80

75

80

80

TEMPERATURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ID WB (°F)

57

62

62

67

72

57

62

62

67

57

57

62

62

67

72

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

49.5

49.2

48.3

52.5

56.2

51.1

49.8

48.8

53.3

56.5

52.7

50.5

49.3

54.0

56.9

65

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

45.3

42.7

35.3

35.1

27.3

46.5

44.4

37.6

37.4

28.8

47.7

46.1

39.9

39.8

30.2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

2.8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

46.0

46.5

45.6

50.2

53.6

47.7

47.4

46.2

50.8

53.9

49.3

48.2

46.9

51.5

54.2

75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

43.1

41.0

34.1

34.2

26.5

44.4

43.0

36.4

36.5

27.9

45.8

45.1

38.8

38.8

29.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.2

3.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

42.6

43.9

42.8

47.9

51.1

44.2

45.0

43.6

48.4

51.2

45.9

46.0

44.4

49.0

51.4

85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

40.9

39.2

32.8

33.4

25.7

42.4

41.6

35.3

35.6

27.1

43.9

44.0

37.7

37.9

28.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.6

3.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

39.1

41.2

40.1

45.6

48.5

40.8

42.5

41.0

46.0

48.6

42.4

43.8

42.0

46.4

48.7

95

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

38.8

37.5

31.5

32.5

25.0

40.4

40.2

34.1

34.7

26.3

42.0

42.9

36.6

36.9

27.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.0

4.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

36.8

38.7

37.4

42.1

44.9

38.3

40.0

38.2

42.5

44.9

39.8

41.2

38.9

42.9

44.8

105

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

36.4

35.9

30.3

31.2

23.8

37.9

38.1

32.5

33.3

25.1

39.3

40.3

34.6

35.5

26.5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

4.6

4.6

4.5

4.6

4.6

4.6

4.6

4.5

4.6

4.6

4.6

4.6

4.6

4.6

4.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

34.5

36.3

34.8

38.8

41.4

35.9

37.5

35.4

39.2

41.2

37.2

38.6

35.9

39.6

41.1

115

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

34.2

34.3

29.2

29.9

22.7

35.5

36.0

30.9

32.0

24.0

36.8

37.7

32.6

34.1

25.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

5.1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T.C.

32.3

33.9

32.2

35.5

37.9

33.5

35.0

32.6

35.8

37.6

34.6

36.1

32.9

36.2

37.3

125

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S.C.

31.9

32.7

28.0

28.6

21.5

33.1

33.9

29.3

30.6

22.9

34.3

35.2

30.6

32.7

24.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

K.W.

5.7

5.6

5.6

5.6

5.6

5.7

5.6

5.6

5.6

5.7

5.7

5.6

5.6

5.6

5.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE: ALL CAPACITIES ARE NET (KBTUH) WITH INDOOR FAN HEAT ALREADY DEDUCTED AT 1250 BTUH/1000 CFM.

Multipliers for determining the performance with other indoor sections.

NOTE: For dry bulb temperatures different than those listed (between 73-87 F), sensible capacity increases by 1060 BTUH per 1000 CFM per degree above the listed temperature and decreases by 1060 BTUH per 1000 CFM per degree below the listed temperature.

Air Handler

Coil

T.C.

S.C.

KW

MA20D

FC/MC60D

1.00

1.00

1.00

MA20D

MC61

1.01

1.02

1.00

MV20D

FC/MC60D

1.02

1.02

1.00

MV20D

FC60C

1.01

1.01

1.00

MV20D

MC61D

1.03

1.03

1.00

AHP/SHP48

1.00

0.96

1.00

AHP/SHP60

1.00

0.96

1.00

AV/SV48

1.01

1.01

1.00

F*FV060

1.01

0.98

1.00

HC60

1.00

0.98

1.00

HD60

1.00

0.97

1.00

MC61

1.01

1.02

1.00

 

 

 

 

 

 

Variable Speed

 

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

 

 

P(C,V)9*D20

 

FC/MC/PC60D

1.00

0.93

1.01

P(C,V)9*D20

 

MC61D

1.01

0.94

1.01

Y*9C*D20

 

FC/MC/PC60D

1.03

1.04

0.98

Y*9C*D20

 

FC/MC62D

1.03

1.05

0.98

Y*(8,L)C*C16

 

FC/PC60C

1.03

1.04

0.98

Y*(8,L)C*C20

 

FC/PC60C

1.03

1.05

0.96

Y*9C*C16

 

FC/PC60C

1.03

1.04

0.99

Variable Speed

Coil

T.C.

S.C.

KW

Furnace

 

 

 

 

Y*9C*C20

FC/PC60C

1.03

1.04

0.99

Y*(8,L)C*C16

HD60

1.02

1.03

0.98

Y*(8,L)C*C20

HD60

1.03

1.04

0.96

Y*9C*C16

HD60

1.02

1.03

0.99

Y*9C*C20

HD60

1.02

1.03

0.99

Y*9C*D20

HD60

1.02

1.03

0.98

Y*(8,L)C*C16

UC60C

1.02

1.02

0.98

Y*(8,L)C*C20

UC60C

1.02

1.02

0.96

Y*9C*C16

UC60C

1.01

1.01

0.99

Y*9C*C20

UC60C

1.01

1.01

0.99

Y*9C*D20

UC60D

1.01

1.01

0.98

G*9V*D20

FC/MC/PC60D

1.03

1.04

0.98

G*9V*D20

FC/MC62D

1.03

1.05

0.98

G*9V*C16

FC/PC60C

1.03

1.04

0.99

G*9V*C20

FC/PC60C

1.03

1.04

0.99

G*9V*C16

HD60

1.02

1.03

0.99

G*9V*C20

HD60

1.02

1.03

0.99

G*9V*D20

HD60

1.02

1.03

0.98

G*9V*C16

UC60C

1.01

1.01

0.99

G*9V*C20

UC60C

1.01

1.01

0.99

G*9V*D20

UC60D

1.01

1.01

0.98

30

Johnson Controls Unitary Products

Page 30
Image 30
York YZB018 THRU 060 warranty Outdoor Unit Model No, YZB04811, Indoor Coil Model No, FC/MC/PC/UC60