Additional
Outdoor Unit | YZB1811 | YZB02411 | YZB03011 | YZB03611 | YZB04211 | YZB04811 | YZB06012 |
Required TXV1 | 1TVM(901/4E1) | 1TVM(902/4F1) | 1TVM(903/4G1) | 1TVM(904/4H1) | 1TVM(904/4H1) | 1TVM(905/4J1) | 1TVM(906/4K1) |
Factory Charge, | |||||||
|
|
|
|
|
|
| |
Indoor Coil2 |
|
| TXV Kit3 | - Additional Charge, Oz |
|
|
Shaded areas indicate matches that require variable speed indoor unit to meet minimum efficiently standards. Data provided for charge adder information only.
FC/MC/PC/UC18A | 901 + 0 | – | – | – | – | – | – |
FC/MC/PC/UC18B | 901 + 0 | – | – | – | – | – | – |
FC/MC/PC/UC24A | – | 902 + 5 | – | – | – | – | – |
FC/MC/PC/UC24B | – | 902 + 5 | – | – | – | – | – |
FC/MC/PC/UC30A | – | 902 + 5 | – | – | – | – | – |
FC/MC/PC/UC30B | – | 902 + 5 | – | – | – | – | – |
FC/MC/PC/UC36A | – | – | 903 + 5 | 904 + 3 | – | – | – |
FC/MC/PC/UC36B | – | – | 903 + 5 | 904 + 3 | – | – | – |
FC/MC/PC/UC36C | – | – | 903 + 5 | 904 + 3 | – | – | – |
FC/MC/PC/UC48C | – | – | – | – | 904 + 7 | – | – |
FC/MC/PC/UC48D | – | – | – | – | 904 + 7 | – | – |
FC/PC/UC60C | – | – | – | – | – | 905 + 12 | – |
FC/MC/PC/UC60D | – | – | – | – | – | 905 + 12 | – |
MC61D | – | – | – | – | – | 905 + 16 | – |
FC/MC62D | – | – | – | – | – | – | 906 + 0 |
HC18A | 901 + 0 | – | – | – | – | – | – |
HC30A | – | 902 + 7 | 903 + 5 | – | – | – | – |
HC36B | – | – | – | 904 + 5 | – | – | – |
HC42C | – | – | – | – | 904 + 5 | – | – |
HC60D | – | – | – | – | – | 905 + 10 | – |
HD24A | 901 + 9 | 902 + 7 | – | – | – | – | – |
HD36B | – | – | 903 + 9 | 904 + 10 | – |
| – |
HD48C | – | – | – | – | 904 + 5 |
| – |
HD60D | – | – | – | – | – | 905 + 10 | – |
AHP18B | 901 + 0 | – | – | – | – | – | – |
AHP24B | – | 902 + 6 | – | – | – | – | – |
AHP30B | – | – | 903 + 9 | – | – | – | – |
AHP36C | – | – | 903 + 14 | 904 + 13 | – | – | – |
AHP42C | – | – | – | 904 + 13 | – | – | – |
AHP/SHP48D | – | – | – | – | 904 + 7 | 905 + 8 | – |
AHP/SHP60D | – | – | – | – | – | 905 + 8 | – |
AV24B | 901 + 3 | 902 + 6 | – | – | – | – | – |
AV36C | – | – | 903 + 14 | 904 + 13 | – | – | – |
AV/SV48D | – | – | – | 904 + 20 | 904 + 10 | 905 + 8 | – |
F*FP024H06T2A | 901 + 0 | – | – | – | – | – | – |
F*FP024H06T2B | 901 + 0 | – | – | – | – | – | – |
F*FP030H06T2A | – | 902 + 3 | – | – | – | – | – |
F*FP036H06T2A | – | – | 903 + 7 | 904 + 5 | – | – | – |
F*FP042H06T2A | – | – | – | 904 + 7 | – | – | – |
FOOTNOTES: |
|
|
|
|
|
|
|
1.If indoor coil comes with a
2.Systems matched with furnace or air handlers not equipped with
3.A TXV kit must be used with these coils to obtain system performance (901, 902, 903, 904, 905 indicates 1TVM …series).
*Does not achieve 13 SEER with PSC furnaces. For ratings, see technical guide or visit www.aridirectory.org/ari/unitary.html.
PROCEDURES:
1.Unit factory charge listed on the unit nameplate includes refrigerant for the condenser, the smallest evaporator and 15 feet of interconnecting line tubing.
2.Verify the TXV and additional charge required for specific evaporator coil in the system using the above table.
3.Additional charge for the amount of interconnecting line tubing greater than 15 feet at the rate specified on the previous page.
4.Permanently mark the unit nameplate with the total system charge. Total System Charge = Base Charge (as shipped) + adder for evaporator + adder for line set.