HEATING CAPACITY - YZB04811With Variable Speed Furnaces |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
VARIABLE | COIL1 |
|
|
|
| ARI HEATING2 |
|
|
| ||
SPEED |
|
|
|
|
|
|
|
|
|
| |
MODEL |
| 47°F |
|
|
|
| 17°F |
| HSPF | ||
FURNACE |
|
|
|
|
|
|
|
|
|
| |
| MBH | COP |
| KW |
| MBH |
| COP | KW | STD | |
|
|
|
|
| |||||||
| 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES |
|
|
| |||||||
P(C,V)9*D20 | FC/MC/PC60D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.32 | 4.14 | 8.50 |
PV8*C20 | FC/PC60C | 48.0 | 3.50 |
| 4.02 |
| 33.2 |
| 2.30 | 4.23 | 8.00 |
P(C,V)9*C20 | FC/PC60C | 48.0 | 3.52 |
| 4.00 |
| 33.0 |
| 2.32 | 4.17 | 8.50 |
PV8*C20 | HC60 | 48.0 | 3.50 |
| 4.02 |
| 33.2 |
| 2.30 | 4.23 | 8.00 |
P(C,V)9*D20 | HC60 | 48.0 | 3.50 |
| 4.02 |
| 33.2 |
| 2.30 | 4.23 | 8.00 |
PV8*C20 | HD60 | 48.0 | 3.50 |
| 4.02 |
| 33.2 |
| 2.30 | 4.23 | 8.00 |
P(C,V)9*D20 | HD60 | 48.0 | 3.50 |
| 4.02 |
| 33.2 |
| 2.30 | 4.23 | 8.00 |
P(C,V)9*D20 | MC61D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.32 | 4.14 | 8.50 |
Y*9C*D20 | FC/MC/PC60D | 47.5 | 3.48 |
| 4.00 |
| 33.0 |
| 2.28 | 4.24 | 8.00 |
Y*9C*D20 | FC/MC62D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
Y*(8,L)C*C16 | FC/PC60C | 47.5 | 3.50 |
| 3.98 |
| 33.0 |
| 2.30 | 4.21 | 8.00 |
Y*(8,L)C*C20 | FC/PC60C | 47.5 | 3.54 |
| 3.93 |
| 32.8 |
| 2.32 | 4.14 | 8.10 |
Y*9C*C16 | FC/PC60C | 47.5 | 3.48 |
| 4.00 |
| 33.2 |
| 2.28 | 4.27 | 8.00 |
Y*9C*C20 | FC/PC60C | 47.5 | 3.48 |
| 4.00 |
| 33.2 |
| 2.28 | 4.27 | 8.00 |
Y*(8,L)C*C16 | HD60 | 47.0 | 3.30 |
| 4.17 |
| 32.6 |
| 2.14 | 4.46 | 7.90 |
Y*(8,L)C*C20 | HD60 | 47.0 | 3.32 |
| 4.15 |
| 32.4 |
| 2.16 | 4.40 | 7.90 |
Y*9C*C16 | HD60 | 47.0 | 3.26 |
| 4.23 |
| 32.6 |
| 2.12 | 4.51 | 7.90 |
Y*9C*C20 | HD60 | 47.0 | 3.26 |
| 4.23 |
| 32.6 |
| 2.12 | 4.51 | 7.90 |
Y*9C*D20 | HD60 | 47.0 | 3.28 |
| 4.20 |
| 32.6 |
| 2.14 | 4.46 | 7.90 |
Y*(8,L)C*C16 | UC60C | 47.5 | 3.56 |
| 3.91 |
| 32.6 |
| 2.32 | 4.12 | 8.10 |
Y*(8,L)C*C20 | UC60C | 47.5 | 3.62 |
| 3.85 |
| 32.4 |
| 2.36 | 4.02 | 8.10 |
Y*9C*C16 | UC60C | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
Y*9C*C20 | UC60C | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
Y*9C*D20 | UC60D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.32 | 4.14 | 8.10 |
G*9V*D20 | FC/MC/PC60D | 47.5 | 3.48 |
| 4.00 |
| 33.0 |
| 2.28 | 4.24 | 8.00 |
G*9V*D20 | FC/MC62D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
G*9V*C16 | FC/PC60C | 47.5 | 3.48 |
| 4.00 |
| 33.2 |
| 2.28 | 4.27 | 8.00 |
G*9V*C20 | FC/PC60C | 47.5 | 3.48 |
| 4.00 |
| 33.2 |
| 2.28 | 4.27 | 8.00 |
G*9V*C16 | HD60 | 47.0 | 3.26 |
| 4.23 |
| 32.6 |
| 2.12 | 4.51 | 7.90 |
G*9V*C20 | HD60 | 47.0 | 3.26 |
| 4.23 |
| 32.6 |
| 2.12 | 4.51 | 7.90 |
G*9V*D20 | HD60 | 47.0 | 3.28 |
| 4.20 |
| 32.6 |
| 2.14 | 4.46 | 7.90 |
G*9V*C16 | UC60C | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
G*9V*C20 | UC60C | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.30 | 4.18 | 8.10 |
G*9V*D20 | UC60D | 48.0 | 3.54 |
| 3.97 |
| 32.8 |
| 2.32 | 4.14 | 8.10 |
Notes listed below. |
|
|
|
|
|
|
|
|
|
|
|
HEATING CAPACITY - YZB06012With Variable Speed Furnaces |
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
| ||
VARIABLE | COIL1 |
|
|
|
| ARI HEATING2 |
|
|
| ||
SPEED |
|
|
|
|
|
|
|
|
|
| |
MODEL |
| 47°F |
|
|
|
| 17°F |
| HSPF | ||
FURNACE |
|
|
|
|
|
|
|
|
|
| |
| MBH | COP |
| KW |
| MBH |
| COP | KW | STD | |
|
|
|
|
| |||||||
| 1 PH 13 SEER HP WITH VARIABLE SPEED FURNACES |
|
|
| |||||||
P(C,V)9*D20 | FC/MC62D | 55 | 3.54 |
| 4.55 |
| 37 |
| 2.46 | 4.35 | 8.65 |
Y*(8,L)C*C20 | FC/MC62D | 56.5 | 3.56 |
| 4.65 |
| 34.0 |
| 2.40 | 4.15 | 8.10 |
Y*9C*C20 | FC/MC62D | 57.0 | 3.50 |
| 4.77 |
| 34.2 |
| 2.36 | 4.25 | 8.00 |
Y*9C*D20 | FC/MC62D | 57.0 | 3.50 |
| 4.77 |
| 34.0 |
| 2.38 | 4.19 | 8.10 |
G*9V*C20 | FC/MC62D | 57.0 | 3.50 |
| 4.77 |
| 34.2 |
| 2.36 | 4.25 | 8.00 |
G*9V*D20 | FC/MC62D | 57.0 | 3.50 |
| 4.77 |
| 34.0 |
| 2.38 | 4.19 | 8.10 |
1.Rated CFM same as for cooling.
2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
Johnson Controls Unitary Products | 21 |