HEATING CAPACITY - YZB03611With Variable Speed Furnaces (Continued) |
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
VARIABLE | COIL1 |
|
|
| ARI HEATING2 |
|
|
| ||
SPEED |
|
|
|
|
|
|
|
|
| |
MODEL |
| 47°F |
|
|
|
| 17°F |
| HSPF | |
FURNACE |
|
|
|
|
|
|
|
|
| |
| MBH | COP | KW |
| MBH |
| COP | KW | STD | |
|
|
|
| |||||||
Y*(8,L)C*C20 | FC/MC/PC48C | 35.4 | 3.58 | 2.90 |
| 23.8 |
| 2.46 | 2.84 | 8.20 |
Y*9C*C16 | FC/MC/PC48C | 35.6 | 3.52 | 2.96 |
| 24.0 |
| 2.42 | 2.91 | 8.20 |
Y*9C*C20 | FC/MC/PC48C | 36.0 | 3.54 | 2.98 |
| 24.2 |
| 2.42 | 2.93 | 8.20 |
Y*(8,L)C*C16 | HC42 | 35.4 | 3.50 | 2.96 |
| 23.8 |
| 2.42 | 2.88 | 8.20 |
Y*(8,L)C*C20 | HC42 | 35.4 | 3.54 | 2.93 |
| 23.8 |
| 2.44 | 2.86 | 8.20 |
Y*9C*C16 | HC42 | 35.6 | 3.46 | 3.02 |
| 24.0 |
| 2.38 | 2.96 | 8.10 |
Y*9C*C20 | HC42 | 35.4 | 3.50 | 2.96 |
| 24.0 |
| 2.42 | 2.91 | 8.20 |
Y*(8,L)C*B12 | HD48 | 34.8 | 3.10 | 3.29 |
| 23.8 |
| 2.10 | 3.32 | 7.90 |
Y*(8,L)C*C16 | HD48 | 34.6 | 3.16 | 3.21 |
| 23.4 |
| 2.14 | 3.20 | 8.00 |
Y*(8,L)C*C20 | HD48 | 34.6 | 3.18 | 3.19 |
| 23.4 |
| 2.14 | 3.20 | 8.00 |
Y*9C*B12 | HD48 | 35.0 | 3.10 | 3.31 |
| 23.8 |
| 2.10 | 3.32 | 7.90 |
Y*9C*C16 | HD48 | 34.8 | 3.14 | 3.25 |
| 23.6 |
| 2.12 | 3.26 | 7.90 |
Y*9C*C20 | HD48 | 35.2 | 3.20 | 3.22 |
| 24.2 |
| 2.18 | 3.25 | 7.90 |
Y*(8,L)C*A12 | UC36A | 35.4 | 3.24 | 3.20 |
| 24.8 |
| 2.24 | 3.24 | 8.00 |
Y*(8,L)C*B12 | UC36B | 35.2 | 3.26 | 3.16 |
| 24.6 |
| 2.26 | 3.19 | 8.00 |
Y*9C*B12 | UC36B | 35.2 | 3.28 | 3.15 |
| 24.6 |
| 2.28 | 3.16 | 8.00 |
Y*(8,L)C*C16 | UC36C | 35.2 | 3.34 | 3.09 |
| 23.8 |
| 2.32 | 3.01 | 8.10 |
Y*(8,L)C*C20 | UC36C | 35.0 | 3.36 | 3.05 |
| 23.8 |
| 2.32 | 3.01 | 8.10 |
Y*9C*C16 | UC36C | 35.2 | 3.36 | 3.07 |
| 23.8 |
| 2.32 | 3.01 | 8.10 |
Y*9C*C20 | UC36C | 35.6 | 3.34 | 3.12 |
| 23.8 |
| 2.26 | 3.09 | 8.00 |
Y*(8,L)C*C16 | UC48C | 35.6 | 3.66 | 2.85 |
| 24.0 |
| 2.52 | 2.79 | 8.30 |
Y*(8,L)C*C20 | UC48C | 35.6 | 3.68 | 2.84 |
| 23.8 |
| 2.54 | 2.75 | 8.30 |
Y*9C*C16 | UC48C | 35.8 | 3.62 | 2.90 |
| 24.0 |
| 2.50 | 2.81 | 8.20 |
Y*9C*C20 | UC48C | 36.2 | 3.64 | 2.91 |
| 24.4 |
| 2.48 | 2.88 | 8.20 |
G*9V*B12 | FC/MC/PC35B | 35.4 | 3.30 | 3.14 |
| 24.0 |
| 2.30 | 3.06 | 8.00 |
G*9V*C16 | FC/MC/PC35C | 35.4 | 3.38 | 3.07 |
| 24.4 |
| 2.36 | 3.03 | 8.10 |
G*9V*C20 | FC/MC/PC35C | 35.8 | 3.38 | 3.10 |
| 23.8 |
| 2.30 | 3.03 | 8.10 |
G*9V*A12 | FC/MC/PC36A | 35.6 | 3.28 | 3.18 |
| 24.2 |
| 2.30 | 3.08 | 8.00 |
G*9V*B12 | FC/MC/PC36B | 35.4 | 3.34 | 3.11 |
| 24.4 |
| 2.36 | 3.03 | 8.00 |
G*9V*C16 | FC/MC/PC36C | 35.2 | 3.42 | 3.02 |
| 24.4 |
| 2.40 | 2.98 | 8.10 |
G*9V*C20 | FC/MC/PC36C | 35.6 | 3.42 | 3.05 |
| 23.6 |
| 2.32 | 2.98 | 8.10 |
G*9V*A12 | FC/MC/PC37A | 35.6 | 3.32 | 3.14 |
| 24.6 |
| 2.34 | 3.08 | 8.00 |
G*9V*B12 | FC/MC/PC43B | 35.8 | 3.42 | 3.07 |
| 24.2 |
| 2.36 | 3.01 | 8.10 |
G*9V*C16 | FC/MC/PC43C | 35.6 | 3.46 | 3.02 |
| 24.0 |
| 2.38 | 2.96 | 8.10 |
G*9V*C20 | FC/MC/PC43C | 35.4 | 3.50 | 2.96 |
| 24.0 |
| 2.42 | 2.91 | 8.20 |
G*9V*C16 | FC/MC/PC48C | 35.6 | 3.52 | 2.96 |
| 24.0 |
| 2.42 | 2.91 | 8.20 |
G*9V*C20 | FC/MC/PC48C | 36.0 | 3.54 | 2.98 |
| 24.2 |
| 2.42 | 2.93 | 8.20 |
G*9V*C16 | HC42 | 35.6 | 3.46 | 3.02 |
| 24.0 |
| 2.38 | 2.96 | 8.10 |
G*9V*C20 | HC42 | 35.4 | 3.50 | 2.96 |
| 24.0 |
| 2.42 | 2.91 | 8.20 |
G*9V*B12 | HD48 | 35.0 | 3.10 | 3.31 |
| 23.8 |
| 2.10 | 3.32 | 7.90 |
G*9V*C16 | HD48 | 34.8 | 3.14 | 3.25 |
| 23.6 |
| 2.12 | 3.26 | 7.90 |
G*9V*C20 | HD48 | 35.2 | 3.20 | 3.22 |
| 24.2 |
| 2.18 | 3.25 | 7.90 |
G*9V*A12 | UC36A | 35.6 | 3.22 | 3.24 |
| 24.8 |
| 2.24 | 3.24 | 7.90 |
G*9V*B12 | UC36B | 35.2 | 3.28 | 3.15 |
| 24.6 |
| 2.28 | 3.16 | 8.00 |
G*9V*C16 | UC36C | 35.2 | 3.36 | 3.07 |
| 23.8 |
| 2.32 | 3.01 | 8.10 |
G*9V*C20 | UC36C | 35.6 | 3.34 | 3.12 |
| 23.8 |
| 2.26 | 3.09 | 8.00 |
G*9V*C16 | UC48C | 35.8 | 3.62 | 2.90 |
| 24.0 |
| 2.50 | 2.81 | 8.20 |
G*9V*C20 | UC48C | 36.2 | 3.64 | 2.91 |
| 24.4 |
| 2.48 | 2.88 | 8.20 |
1.Rated CFM same as for cooling.
2.Heating MBH based on ARI standards of 70° DB entering indoor air, 72% RH outdoor air with 25 feet of interconnecting piping and no supplemental electric heat operation.
CP equals MBH output divided by (total KW input x 3.412).
HSPF (Heating Seasonal Performance Factor) is the total heating output during a normal annual usage period for heating divided by the total electric power input during the same period.
Johnson Controls Unitary Products | 19 |