SPECIFICATIONS

Shock

MIL-STD-810E (Method 516) 30 g’s

 

 

 

MIL-S-901D (in isolated rack)

 

 

Fungus

Non-Nutrients/Contaminants

 

 

Sand and Dust

5.5 MPH for 25 mins (display bezel only)

 

 

Drip

MIL-STD-810E (display bezel only)

 

 

Reliability

 

 

 

MTBF

Display: 20,000 hrs w/ backlight change at 10,000

 

hrs.

 

 

MRRT

<30 minutes

 

 

Safety

UL 1950 (Used as a design guideline)

 

 

EMI

FCC Class A

 

 

Quality/Workmanship

IPC/ISO 9001:2000 and applicable section of

 

MIL-HDBK-454

 

 

* Results of Environmental Tests pending

** Unit will power up and is legible at -20°C; backlight life is reduced

40

Doc# 27-0023UM Rev 1.0 Issued 09/04