18
Fig. 10
Building In

On base cabinet with door

Proper arrangements must be
ensured in the construction of the
cabinet, to prevent possible contact
with the overheated housing of the top
during operation. The recommended
solution for avoiding this problem is
illustrated in fig. 9.
The panel under the top must be
easily removed to allow securing and
release of the top in case of technical
service intervention.

On base cabinet with oven

The hob recess dimension must
comply with the indication given in fig. 7
and must be provided with brackets to
allow a continuous supply of air.
Two possible solutions for preventing
overheating are described in fig. 10 and
11.
The electrical connection of the hob
and of the oven must be carried out
separately, both for safety reasons and
toallow the oven to be easily taken off
the unit.
Wall units or extractor hoods must be
at least 650 mm from the cooktop (Fig.
7).
Fig. 9 aa
aa
a) removable cabinet panel
bb
bb
b) possible space useful for
connections
Fig. 11
30
20 min
80
a
b
120 cm
2
180 cm
2
360 cm2
50 cm2