Residual heat indicator
An “H” will light up in the power level indicator if the temperature of the corresponding cooking zone sur- face above 60°C. When the cooking zone has been switched off, the lamp remains on until temperature falls below 60°C.
Pay attention when a pan/pot is left on the coo- king zone that the residual heat indicator can switch off though is the cooking zone still hot from the pan with hot contents.
Operation
The touch controls must be pressed for at least
1 second to be activated, which will be indicated by an acoustic signal.
Switching the appliance on
1.Press the hob ON/OFF control (1) for at least 1 se- cond.
A horizontal line appears in each power level indicator (3), and the dot (13) flashes.
The next input must take place within the next 10 seconds, otherwise the hob will switch off again.
Switching on the cooking zones
Having switched on the appliance with the hob ON/ OFF control (1), you can now switch on the various cooking zones within the next 10 seconds.
1.Press the cooking zone control (2) for the required cooking zone.
«0» lights up on the corresponding power level in- dicator. At the same time, dot (13) lights up to indi- cate which cooking zone is active.
2.Select a power level
3 13
1
2
If you selct the power level using the increase control, the boost facility will be activated (see pages 66).
The increase/decrease controls (5/4) are equipped with a repeat function. If one of the keys is continually pressed, the power level will be increased.
Only one cooking zone control (2) can be ac- tive at a time, that is, only one dot (13) can be lit up.
5
4
13