INSTALLATION INSTRUCTIONS
PRESSURE TESTING
To pressure test connect the pressure gauge to the main oven injector
1Check the supply pressure by turning the grill on and oven thermostat to Mark 9. Then turn on the electricity supply. Allow the grill burner to light.
The pressure should be:
Natural Gas | 20mbar |
L.P.G. Gas | The pressure must be set to |
| 28mbar for use on butane |
| or 37mbar for use on |
| propane. |
2 Turn off the electricity supply and the thermostat; disconnect the pressure gauge.
ZUG 78 - 311359904