PRESSURE TESTING

INSTALLATION INSTRUCTIONS

PRESSURE TESTING

To pressure test connect the pressure gauge to the main oven injector

1Check the supply pressure by turning the grill on and oven thermostat to Mark 9. Then turn on the electricity supply. Allow the grill burner to light.

The pressure should be:

Natural Gas

20mbar

L.P.G. Gas

The pressure must be set to

 

28mbar for use on butane

 

or 37mbar for use on

 

propane.

2 Turn off the electricity supply and the thermostat; disconnect the pressure gauge.