Printer Operation
Calibrate the Printer
Calibrate the PrinterCalibrate the printer when it is first put into service. Calibration allows the printer to establish the proper settings for the specific media and ribbon used in your application. You may calibrate the printer at other times as needed. Table 5 shows the different methods for calibration.
Table 5 • Types of Calibration
Type of Calibration | Description | When/How It Occurs |
|
|
|
The printer automatically sets the | Occurs at the following times: | |
| value it detects for the spaces | • When the printer is first turned on |
| between labels. | if CALIBRATION is selected for |
|
| MEDIA POWER UP (see Media |
|
| |
|
| • When the printer feeds media after |
|
| the printhead is closed if |
|
| CALIBRATION is selected for |
|
| HEAD CLOSE (see Head Close |
|
| |
|
| • As part of both the sensor profile |
|
| and media and ribbon sensor |
|
| calibration procedures. |
|
|
|
Long (Standard) | The printer does the following: | To perform a long calibration, do one |
Calibration | • feeds media and ribbon | of the following: |
| • sets the values it detects for media | • Press PAUSE on the front panel to |
| length, media type (continuous or | pause the printer, and then press |
| CALIBRATE. | |
| (thermal transfer or direct thermal) | • Select CALIBRATION for the |
| • updates the sensor values | MEDIA POWER UP or HEAD |
|
| CLOSE parameter (see Media |
|
| |
|
| |
|
|
|
Short Calibration | The printer calibrates using the | Select SHORT CAL for the MEDIA |
| current sensor values rather than | POWER UP or HEAD CLOSE |
| detecting the spaces between labels | parameter (see Media Power Up |
| and resetting the sensors. This | |
| calibration sequence uses fewer | |
| labels than the long calibration |
|
| sequence, but it is less reliable |
|
| because the values that are stored in |
|
| the sensors could be incorrect. |
|
|
|
|
R110Xi/R170Xi User Guide | 35 |