Front Panel Controls

Front Panel LCD

 

Table 7 • Standard LCD Displays (Page 10 of 16)

 

 

Parameter

Action/Explanation

 

 

FORMAT PREFIX

Format Prefix Character

 

The format prefix is a two-digit hex value used as a parameter place marker in

 

ZPL/ZPL II format instructions. The printer looks for this hex character to indicate

 

the start of a ZPL/ZPL II format instruction. See the ZPL II Programming Guide

 

Volume I for more information.

 

Note • Do not use the same hex value for the control, format, and delimiter

 

character. The printer must see different characters to work properly.

 

1. Press the left oval to move to the next digit position.

 

2. Press the right oval to increase the value of the digit.

 

Default: 5E (caret)

 

Range: 00 to FF

 

 

DELIMITER CHAR

Delimiter Character

 

The delimiter character is a two-digit hex value used as a parameter place marker in

 

ZPL/ZPL II format instructions. See the ZPL II Programming Guide Volume I for

 

more information.

 

Note • Do not use the same hex value for the control, format, and delimiter

 

character. The printer must see different characters to work properly.

 

1. Press the left oval to move to the next digit position.

 

2. Press the right oval to increase the value of the digit.

 

Default: 2C (comma)

 

Range: 00 to FF

 

 

ZPL MODE

Selecting ZPL Mode

 

The printer remains in the selected mode until it is changed by this front panel

 

instruction or by using a ZPL/ZPL II command. The printer accepts label formats

 

written in either ZPL or ZPL II, eliminating the need to rewrite any ZPL formats

 

that already exist. See the ZPL II Programming Guide for more information on the

 

differences between ZPL and ZPL II.

 

• Press the right or left oval to display other choices.

 

Default: ZPL II

 

Selections: ZPL II, ZPL

 

 

23063L-003 Rev. 2 12/23/04

R110Xi/R170Xi User Guide

53