Front Panel Controls

Front Panel LCD

 

Table 7 • Standard LCD Displays (Page 12 of 16)

 

 

Parameter

Action/Explanation

 

 

BACKFEED

Backfeed Sequence

 

This parameter establishes when and how much label backfeed occurs after a label

 

is removed or cut in Peel-Off, Cutter, and Applicator modes. It has no effect in

 

Rewind or Tear-Off modes. This parameter setting can be superseded by the ~JS

 

instruction when received as part of a label format (see the ZPL II Programming

 

Guide).

 

Note • The difference between the value entered and 100% establishes how much

 

backfeed occurs before the next label prints. For example, a value of 40 means that

 

40% of the backfeed takes place after the label is removed or cut. The remaining

 

60% takes place before the next label prints. A value of BEFORE means that all

 

backfeed takes place before the next label prints.

 

• Press the right or left oval to display other choices.

 

Default: DEFAULT (90%)

 

Selections: DEFAULT, AFTER, OFF, BEFORE, 10%, 20%, 30%, 40%, 50%,

 

60%, 70%, 80%

 

 

LABEL TOP

Adjusting Label Top Position

 

The label top position adjusts the print position vertically on the label. Positive

 

numbers adjust the label top position further down the label (away from the

 

printhead), negative numbers adjust the position up the label (toward the printhead).

 

The displayed value represents dots.

 

• To increase the value, press the right oval.

 

• To decrease the value, press the left oval.

 

Default: +0

 

Range: –120 to +120 dot rows

 

 

LEFT POSITION

Adjusting Left Position

 

This parameter establishes how far from the left edge of a label the format begins to

 

print by adjusting horizontal positioning on the label. Positive numbers adjust the

 

printing to the left by the number of dots selected; negative numbers shift printing

 

to the right.

 

The displayed value represents dots.

 

1. Press the left oval to move the cursor.

 

2. Press the right oval to change between + and to increase the value of the digit.

 

3. For a negative value, enter the value before changing to the minus sign.

 

Default: 0000

 

Range: –9999 to +9999

 

 

23063L-003 Rev. 2 12/23/04

R110Xi/R170Xi User Guide

55