Chapter 3 SHD1111 Programming

0: OFF

 

 

 

 

 

1-99: ON

(Binary Switch Device)

 

 

Dim Level (Multilevel Switch Device)

 

 

 

 

 

 

 

 

FUNCTION

 

PARAMETER

SIZE (BYTE)

RANGE

DEFAULT

Basic Set Level

1

1

0~99

99

 

 

 

 

 

 

3.1.3.2 Configuring the OFF Delay

Configuration Parameter #2 can adjust the time of delay before the OFF command is transmitted. This parameter can be set from of 1 ~ 127 seconds of delay.

FUNCTION

PARAMETER

SIZE (BYTE)

RANGE

DEFAULT

Basic Set Level

2

1

1~127

1

 

 

 

 

 

3.2 Advanced Programming

3.2.1 Battery Check Command

The Z-Wave Controller may enquire the battery status of the SHD1111 by sending BATTERY_ GET. Once the SHD1111 receives the command, it will return BATTERY_REPORT command to the controller.

BATTERY_REPORT

[Command Class Battery, Battery Report, Battery Level = 20%-100%]

If the message shows "Battery Level = 255 (0xFF)", it implies that the SHD1111 is at low battery status. Please replace the batteries as soon as possible, otherwise the SHD1111 will shut down.

3.2.2 Wakeup Command Class

The SHD1111 stays in sleep status for the majority of time in order to conserve battery power. However, it can be waken up by the WAKE_UP_INTERVAL_SET command set by the Z-Wave Controller.

After the SHD1111 wakes up, it will send Wakeup Notification Command to its association nodes and stay awake for 5 seconds if it doesn’t receive any WAKE_UP_NO_MORE_INFORMATION command.

The minimum and maximum wakeup interval is 60 seconds and 194 days respectively. Allowable interval among each wakeup interval is 1 second.

FUNCTION

DEFAULT

Basic Set Level

99

 

 

Period of Wake Up Notification

1 hour

 

 

14

 

Z-Wave Series Programming Guide