Chapter 2 SHD1110 Programming

Table 1 Z-Wave Configuration Table (continued)

PARAMETER

FUNCTION

SIZE (BYTE)

VALUE

UNIT

FACTORY

DESCRIPTION

DEFAULT

 

 

 

 

 

 

7

Auto Report

1

1~70

Degree

0 / 0

Set auto report

 

(Temp.

 

or

 

 

temp. trigger interval

 

Change)

 

0

 

 

to be _ degree.

 

 

 

 

 

 

0: Disable auto

 

 

 

 

 

 

report

 

 

 

 

 

 

 

8

Auto Report

1

5~70

%

0 / 0

Set auto report

 

(Humid.

 

or

 

 

humid. trigger

 

Change)

 

0

 

 

interval to be _ %.

 

 

 

 

 

 

0: Disable auto

 

 

 

 

 

 

report

 

 

 

 

 

 

 

Note: Once the SHD1110 is reset, it will be restored to its factory default status and settings.

2.1.4 Auto Report

2.1.4.1 Time Interval

You can set the SHD1110 to automatically send out reports of its current status to Grouping 1 at a set time. The time interval can be set from 1 minute to 24 hours. For instance, if time interval is set to 1 minute, the SHD1110 will report its status once per minute.

Refer to parameter 6 of the Z-Wave Configuration Table.

2.1.4.2 Temperature Change

You can set the SHD1110 to automatically send out reports of temperature status to Grouping 1 once the temperature exceeds the set degree. The temperature difference range can be set from 1oC to 70oC. For instance, if the temperature is set to 28oC, the SHD1110 will report its current temperature status once the temperature exceeds 28oC.

Refer to parameter 7 of the Z-Wave Configuration Table.

2.1.4.3 Humidity Change

You can set the SHD1110 to automatically send out reports of humidity status to Grouping 1 once the humidity exceeds the set %RH. The humidity difference range can be set from 5%RH to 70%RH. For instance, if the temperature is set to 50%RH, the SHD1110 will report its current humidity status once the humidity exceeds 50%RH.

Refer to parameter 8 of the Z-Wave Configuration Table.

Note: Auto report function may cause a lot of power consumption if it operates often. Consider the actual requirements for enabling this function and setting the time interval.

 