Chapter 4 SHD2110/3110 Programming
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value 3*256) + (Meter Value 4) = 70.1 (KW/h)
Meter Report Command
[Command Class Meter,Meter Report,Rate
Type+Meter Type, Precision+Scale+ Size, Meter Value 1, Meter Value 2]
4.2.4.3 Clearing Accumulated Power Consumption
Meter Reset Command
[Command Class Meter, Meter Reset]
4.2.5 Command Classes
The SHD2110/3110 supports the following Command Classes:
•COMMAND_CLASS_SWITCH_BINARY
•COMMAND_CLASS_BASIC
•COMMAND_CLASS_MANUFACTURER_SPECIFIC
•COMMAND_CLASS_VERSION
•COMMAND_CLASS_SWITCH_ALL
•COMMAND_CLASS_ASSOCIATION_V2
•COMMAND_CLASS_METER_V2
•COMMAND_CLASS_ALARM
•COMMAND_CLASS_CONFIGURATION
20 |
|
|
|