Chapter 2 SHD1110 Programming

2.1.5 Wakeup Configuration

The SHD1110 stays in sleep status for the majority of time in order to conserve battery power. However, it can be waken up by either triggers of temperature/humidity or set time for the Z-Wave Controller to enable further settings.

2.1.5.1 Wakeup Time Interval

The SHD1110 stays awake for 10 seconds. If the SHD1110 receives a RF command from the Z- Wave Controller during this period, the waking time will be extended for another 10 seconds until no more RF command is received. Once the wakeup time is up, the SHD1110 goes back to sleep status.

2.1.5.2 Sleep Time Interval

The sleep interval can be set from 1 minute to 4660 hours (about 194 days). The unit of time is in seconds. The default sleep time interval is 1 hour.

2.1.6 Command Classes

The SHD1110 supports the following Command Classes:

COMMAND_CLASS_BASIC

COMMAND_CLASS_VERISON

COMMAND_CLASS_BATTERY

COMMAND_CLASS_WAKE_UP_V2

COMMAND_CLASS_CONFIGURATION

COMMAND_CLASS_ASSOCIATION_V2

COMMAND_CLASS_MANUFACTURER_SPECIFIC

COMMAND_CLASS_SENSOR_MULTILEVEL_V2

COMMAND_CLASS_MULTI_INSTANCE_V2

12

 

Z-Wave Series Programming Guide