SHD1110 Programming

2.1 Z-Wave Groups (Association Command Class Version 2)

On the Z-Wave Controller, you can set the SHD1110 to send reports of itself (including power, temperature, humidity, and battery status) to associated nodes of Grouping 1 or control associated Z-Wave devices of Grouping 2. Grouping 1 supports one node and Grouping 2 supports up to three nodes.

2.1.1 Grouping 1

Grouping 1 includes the following commands: POWER_APPLIED, SENSOR_MULTILEVEL _REPORT, ALARM_REPORT and BATTERY_REPORT_COMMAND.

2.1.1.1 POWER_APPLIED command

When power is applied to the SHD1110, the ALARM_REPORT command will be sent to Grouping 1 to inform that the SHD1110 is powered up.

ALARM_REPORT Command

[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]

2.1.1.2 MULTILEVEL_SENSOR_REPORT

The SHD1110 automatically sends out SENSOR_MULTILEVEL_REPORT, containing its current temperature and humidity, to Grouping 1. Refer to the Z-Wave’s Configuration section on page 10 for settings of auto report configuration.

Humidity

The following parameters are used in this example:

Sensor Value 1 = 0x23

Humidity Value = Sensor Value = 35 (%)

SENSOR_MULTILEVEL_REPORT

[Command Class Sensor Multilevel, Sensor Multilevel Report, Sensor Type = 0 x 05 (Relative Humidity), Precision+Scale+Size = 0 x 01, Sensor Value 1 = 20- 90%]

 