Chapter 4 SHD2110/3110 Programming
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: the load attached to the Module turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load attached to the Module turns off.
4.2 Z-Wave Groups (Association Command Class Version 2)
On the
4.2.1 Grouping 1
Grouping 1 includes the following commands: POWER_APPLIED, SWITCH_BINARY_REPORT, and METER_REPORT_COMMAND.
4.2.1.1 POWER_APPLIED command
When the SHD2110/3110 is properly connected to a wall outlet, the ALARM_REPORT command will be sent to Grouping 1 to inform that the SHD2110/3110 is powered up.
ALARM_REPORT Command
[Command Class Alarm, Alarm Type = 0x02, Alarm Level = 0x01]
4.2.1.2 On/Off Event Report (True State)
When you toggle the On/Off button on the SHD2110/3110, the Switch Binary Report is sent to Grouping 1. However, if a specified period of time (the "true period") is set (Section 4.2.3.1 on page 18), toggling the On/Off button will not send Switch Binary Report instantly.
When you initially press the On/Off button, the SHD2110/3110 is locked until the preset true period is over. As soon as the true period is over and the SHD2110/3110 is unlocked, the device will check if the current state is different from the initial state. If it is different, the SHD2110/3110 will send Switch Binary Report to Grouping 1 immediately; whereas if it is the same, the SHD2110/3110 will not send the report to Grouping 1.
You can set the true period through configuration command class. Refer to the true period of configuration.
4.2.1.3 Binary Switch Report Command
ON
[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]
OFF
[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]
| 17 |
|
|