Chapter 19
The following table describes the labels in this screen.
Table 61 RMON Alarm: Create New Alarm
LABEL | DESCRIPTION |
RMON MIB | Use this drop down list box to select the MIB table you want to view. Click Apply to |
Table: | refresh the screen to the selected MIB table view. |
|
|
Index | This field displays the index number of this alarm entry. |
|
|
Interface | Select the port which is monitored for this alarm. |
|
|
Counter | Select the data which is used to test if this alarm is triggered, the choices are Drop |
| Events, Octets, Packets and so on. |
Sample Type | Select the method of obtaining the sample value. Choices are Absolute and Value. |
|
|
Startup Alarm | Select the startup alarm type (Rising Threshold, Falling Threshold, Rising Or |
| Falling Threshold). |
Rising | Specify a rising threshold (between 0 and 2147483647). When a value is greater or |
Threshold | equal to this threshold, the probe triggers an alarm. |
|
|
Falling | Specify the falling threshold (between 0 and 2147483647). When a value is smaller |
Threshold | or equal to this threshold, the probe triggers an alarm. |
|
|
Rising Event | Select an index number of a rising event. |
|
|
Falling Event | Select an index number of a falling event. |
|
|
Owner | Enter a descriptive name of the application that creates this entry. You can use |
| printable ASCII characters. Spaces are not allowed. |
|
|
Apply | Click this to save the settings to the switch. |
|
|
Alarm Overview | Click this to go back to the RMON Alarm: Overview screen. |
|
|
19.6 RMON Event: Overview
Use the RMON Event: Overview screen to view and delete event entries configured on the
switch. Select [9] Event from the RMON MIB Table: drop down listbox in the
Figure 80 RMON Event: Overview.
| 129 |
|
|