TROUBLESHOOTING GUIDE

PROBLEM

 

CAUSE

 

CORRECTION

 

 

 

 

 

Engine will not

1.

Low on fuel or oil.

1.

Add fuel or oil.

start

2.

Ignition switch in "Off"

2.

Turn to "ON" position

 

 

 

position.

 

 

 

3.

Faulty spark plug.

3.

Replace spark plug.

 

4.

Choke in wrong position.

4.

Adjust choke accordingly.

 

5.

Fuel shut-off valve in

5.

Open fuel shut-off valve.

 

 

closed position

 

 

 

6.

Unit loaded during start-

6.

Remove load from unit.

 

 

up.

 

 

 

7.

Spark plug wire loose.

7.

Attach wire to spark plug.

 

 

 

 

 

No electrical

1.

Faulty receptacle.

1.

Have Service Center

output

2.

Circuit breaker kicked

 

replace.

 

2.

Depress and reset.

 

 

out.

 

 

 

3.

Defective capacitor.

3.

Have Service Center

 

 

 

 

replace capacitor.

 

4.

Faulty power cord.

4.

Repair or replace cord.

 

5.

GFCI switch breaker

5.

Depress and reset

 

 

kicked out (if equipped)

 

 

Repeated

1.

Overload

1.

Reduce load.

circuit breaker

2.

Faulty cords or

2.

Check for damaged, bare,

tripping

 

equipment

 

or frayed wires on

 

 

 

 

 

 

 

equipment. Replace.

 

 

 

 

 

Generator

1.

Generator overloaded.

1.

Reduce load.

overheating

2.

Insufficient ventilation.

2.

Move to adequate supply

 

 

 

 

 

of fresh air.

No auto idle

1.

Faulty solenoid

1.

Have Service Center

 

 

 

 

replace.

 

2.

Faulty idle control switch

2.

Have Service Center

 

 

 

 

replace.

 

3.

Faulty windings in stator

3.

Have Service Center

 

 

 

 

replace.

 

4.

Faulty circuit board

4.

Have Service Center

 

 

 

 

replace.

 

5.

Faulty wire harness

5.

Have Service Center

 

 

 

 

replace.

DC does not

1.

Faulty rectifier

1.

Have Service Center

have power

 

 

 

replace.

with the

2.

Faulty windings in stator

2.

Have Service Center

circuit breaker

 

 

 

replace.

depressed

3.

Faulty wire harness

3.

Have Service Center

 

 

 

 

 

replace.

 

 

 

 

 

25- ENG

A01296

Image 25
Contents Generator Consumer Safety Information Safety Guidelines / DefinitionsImportant Safety Instructions Risk of Electrocution and FireRisk of Electrocution and Fire When installing a DoubleBe used OperationUnit Indoors or in ANY Risk of FireConfined Area Risk of Breathing Inhalation Hazard Risk of Unsafe Operation Risk of Moving Parts Risk of HOT SurfacesRisk from Lifting Specifications Consumer General and Service InformationAssembly Read and understand all safety warningsAssemble Wheel KIT UnpackingHole in Axle Without the holeExtended Hub ENG Assemble Skyhook ENG Grounding the Generator Extension Cord Wire Gauge Chart Amperage Length Size Double Throw Transfer SwitchObtaining Electricity from the Generator Extension CordsOperation 12V DC Outlet Idle ControlBefore Start UP Choose the correct applicationTo Start the Engine Connecting Electrical LoadsStopping Engine Engine speed has been factory set to provide safe operationConnecting Procedure for Raising or Suspending Generator Maintenance Storage BatteryEngine Preparation GeneratorDetermining Wattage Requirements Wattage CalculationsRunning Watts Starting Watts 250 500 Starting Wattage Requirements1000 Appliance or Load Device Typical Device Wattage Total Household Wattage CalculatorStart Troubleshooting GuideResponsibility of Original Purchaser initial User Limited WarrantyENG Quick Facts