La Crosse Technology WS-7394U VII. Mounting, Mounting the Remote Temperature Sensor

Page 19

VII. MOUNTING

Note: Before permanently mounting, ensure that the indoor weather station is able to receive signals from the sensors and WWVB signal at the desired location. To achieve a true temperature reading, avoid mounting the remote temperature sensor (or any sensor) where direct sunlight can reach the remote sensor. We recommend that you mount the remote sensor on a North-facing wall or under an eve. The sending range of the remote temperature sensor is 300-ft (100m) however obstacles such as walls, concrete, and large metal objects can reduce the range. Place all units in their desired location, and wait approximately 15 minutes before permanently mounting to ensure that there is proper reception. If the indoor weather station loses the signal from the remote sensor, it will display the last temperature reading for 15 minutes. After 15 minutes of not receiving any signals, the remote temperature will display “- -.-”.

A.Mounting the Remote Temperature Sensor

The remote temperature sensor can be mounted in two ways:

with the use of screws

using the adhesive tape

1.MOUNTING WITH SCREWS

a.Remove the mounting bracket from the remote temperature sensor.

b.Place the mounting bracket over the desired location.

c.Through the three screw holes of the bracket, mark the mounting surface with a pencil.

d.Screw mounting bracket onto the mounting surface. Ensure that the screws are flush with the bracket.

e.Insert the remote temperature sensor into the bracket.

2.MOUNTING WITH ADHESIVE TAPE

a.With a nonabrasive solution, clean and dry the back of the mounting bracket and the mounting surface to ensure a secure hold. The mounting surface should be smooth and flat.

b.Remove the protective strip from one side of the tape.

c.Adhere the tape to the designated area on the back of the mounting bracket.

d.Remove the protective strip from the other side of the tape.

e.Position the remote temperature sensor in the desired location, ensuring that the indoor weather station can receive the signal.

19

Image 19
Contents WS-7394U Wireless 433 MHz Wireless Weather Station Table of Contents Inventory of Contents Do not Press ANY Buttons for 15 Minutes Quick SET-UP GuideIndoor Weather Station Battery InstallationRemote Temperature and Humidity Sensor Detailed SET-UP GuideWwvb Reception II. Start Up Sequence Initial StartIII. Explanation of LCD Information IV. Function Key Layout Program ModeOverview of programming mode sequence LCD Contrast SettingDST ON/OFF Setting Time Zone SettingRadio-controlled Time ON/OFF Setting Setting The Hour Manually 12/24-hour Time ModeSetting The Minutes Manually Setting The Month Manually Setting The Year ManuallySetting The Date Manually Relative Pressure Setting Temperature Measuring Units Selection F or CAir Pressure Measuring Units Selection inHg/hPa Manual Setting is NOW Completed Forecast Sensitivity SettingOutdoor Minimum and Maximum Temperature Features and OperationsSet Up of Multiple Units Multiple Remote Temperature SensorsViewing and Operating with Multiple Remote Sensors Weather Forecast Icon and Pressure Trend Indicators Comfort Indicator for Indoor Temperature and HumidityWeather Icons Weather Tendency Arrows Air Pressure History Bar ChartBarometric Air Pressure Reading Page Mounting with Adhesive Tape Mounting the Remote Temperature SensorVII. Mounting Mounting with ScrewsMaintenance and Care Instructions Using the Table StandWall Mounting Problem TroubleshootingSolution Specifications Warranty Information Support@lacrossetechnology.com