Raypak 122-322 manual Installation & Operating Instructions

Page 1

INSTALLATION & OPERATING

INSTRUCTIONS

Models 122–322 Types H, WH & P

L

W

WARNING: If these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors and liquids or other combustible materials in the vicinity of this or any other appliance. To do so may result in an explosion or fire.

WHAT TO DO IF YOU SMELL GAS:

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

This manual should be maintained in legible condition and kept adjacent to the heater or in another safe place for future reference.

CATALOG NO. 1000.53H

Effective: 09-19-08

Replaces: 11-16-07

P/N 241112 Rev. 9

Image 1
Contents Installation & Operating Instructions Page Contents Are important but not related to personal injury hazards Installations at Elevation Before InstallationProduct Receipt Model IdentificationComponent Locations-Back Component LocationsModel Quantity Vent Size Burners Gas Valves Blowers Flue General InformationModel Burners per Valve Stages Fire at Stage Time/Temperature Relationships in Scalds General SafetyWater Time to Produce Serious Temp Burn Installation Codes InstallationIndoor Installations Equipment BaseHeater Min. Clearance Recommended From Combustible Outdoor InstallationsCombustion and Ventilation Air InstallationsConventional Combustion Air Supply Indoor UnitsWater Piping Canadian InstallationsGeneral Relief Valve PipingHydronic Heating Dual Boiler-Primary/Secondary Piping Piping-Heating Boilers Domestic Hot Water PipingAir-Separation/Expansion Tank Three-Way ValvesSingle Heater-Domestic Hot Water with One Storage Tank Gas Supply Pool HeatingAutomatic Chlorinators and Chemical Feeders Winterizing Your HeaterGas Pressure Regulator Gas Supply Connection Gas Supply PressureCheck the Power Source Electrical Power ConnectionsSurge Protection Making the Electrical ConnectionsSingle Stage and 2-Stage Tankstat Electrical Connections-Domestic Hot WaterDefinition of Appliance Categories VentingSupport of Vent Stack Barometric DamperVent Terminal Location Table I Vent/Air Inlet Termination Clearances Canada Installations US InstallationsVenting Configurations Venting Installation TipsNatural Draft Vertical Vent Termination Natural Draft Vertical Venting System InstallationCategory Inches Length feet Model Appliance Certified Vent Size Max. VentingHorizontal Thru-wall Direct Vent Termination Venting Air Intake Certified Max Combustion Air Inlet Max. AirCategory Inches Length FeetHorizontal Thru-wall Direct Vent Termination Venting Min./Max Combustion Max. Air CertifiedCategory Inches Height InchesVertical Direct Vent System Installation Outdoor InstallationVertical Direct Vent Termination Controls High Limit Manual ResetIgnition Control Module Low Water Cut Off Optional Flow SwitchWiring DIAGRAM-MODELS Initial START-UP PRE-START-UPSafety Inspection Main Burner AdjustmentStart-Up Operation Post START-UP CheckFollow-Up Operating InstructionsSuggested Minimum Maintenance Schedule MaintenanceTo Turn Off Gas To Appliance Yearly Beginning of each heating seasonInside Combustion Air Contamination AppendixMonthly QuarterlyCorporate Headquarters Page
Related manuals
Manual 56 pages 23.48 Kb

122-322 specifications

Raypak 122-322 is a cutting-edge pool and spa heater designed for optimal performance and efficiency. Known for its robust construction and reliable heating capabilities, this heater has become a preferred choice among pool owners.

One of the standout features of the Raypak 122-322 is its advanced copper fin tube heat exchanger. This innovative technology enhances the heater's efficiency by maximizing heat transfer while minimizing energy consumption. By efficiently circulating the water through the heat exchanger, the Raypak 122-322 quickly raises the temperature, allowing for an enjoyable swimming experience regardless of the weather.

The heater is equipped with a digital control system that allows for precise temperature adjustments. This user-friendly interface makes it easy to set and maintain the desired water temperature, promoting user convenience. The digital controls also provide diagnostic features, which simplify troubleshooting and maintenance, ensuring the heater operates smoothly for years to come.

Safety is a crucial aspect of the Raypak 122-322. It comes with a series of safety features, including a flame rollout switch, high limit switch, and a pressure switch that ensures the unit operates safely under various conditions. This focus on safety provides peace of mind for users, knowing that their heating system is designed with protective measures in place.

The Raypak 122-322 is environmentally friendly, designed to use less energy compared to conventional heating systems. Its efficient performance not only reduces operational costs but also lessens the overall environmental impact, making it a responsible choice for conscious consumers.

With a compact design, the Raypak 122-322 can fit easily into various installation spaces, making it versatile for numerous residential or commercial settings. Additionally, the unit is built with durable materials resistant to corrosion and weather conditions, ensuring longevity and minimal maintenance requirements.

Overall, the Raypak 122-322 stands out in the market due to its advanced features, safety mechanisms, energy efficiency, and ease of use. It exemplifies a perfect blend of innovation and reliability, making it an exceptional option for anyone looking to enhance their pool or spa experience.