Fig. 12: Sediment Trap Orientation

Gas Supply Connection

CAUTION: The heater and its manual shutoff valve must be disconnected from the gas supply during any pressure testing of the gas supply system at test pressures in excess of 1/2 PSIG (3.45 kPa). The heater must be isolated from the gas supply piping system by closing the manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 PSIG. Relieve test pressure in the gas supply line before reconnecting the heater and its manual shut off valve to the gas supply line. FAILURE TO FOLLOW THIS PROCEDURE MAY DAMAGE THE GAS VALVES. Over pressurized gas valves are not covered by warranty. The heater and its gas connections shall be leak tested before placing the appliance in operation. Use soapy water for leak test: DO NOT use open flame.

CAUTION: Do not use Teflon tape on gas line pipe thread. A pipe compound rated for use with gas systems is recommended. Apply sparingly only on male pipe ends.

CAUTION: Support gas supply piping with hangers, not by the heater or its accessories. Ensure the gas piping is protected from physical damage and freezing where required.

Gas Supply Pressure

A minimum of 7 in. WC and a maximum of 10.5 in. WC upstream gas pressure is required under load and no load conditions for natural gas. A minimum of 11 in. WC and a maximum of 13 in. WC is required for propane gas. The gas pressure regulator supplied on the heater is for low pressure service. If upstream pressure exceeds 14 in. WC, an intermediate gas pressure regulator, of the lockup type, must be installed.

When connecting additional gas utilization equipment to the gas piping system, the existing piping must be checked to determine if it has adequate capacity.

Gas Pressure Regulator

The gas valve pressure regulator(s) on the heater are nominally preset at 3.5 in. WC for natural gas, and

10.5in. WC for propane gas manifold pressure. The pressure at the gas valve outlet tap, measured with a manometer,while in operation should be 3.5 ± 0.1 in. WC for natural gas and 10.5 in. ± 0.1 in. WC for propane gas. If an adjustment is needed, turn the adjustment screw clockwise to increase pressure or counter-clockwise to decrease pressure.

18

Image 18
Contents Installation & Operating Instructions Page Contents Are important but not related to personal injury hazards Product Receipt Before InstallationInstallations at Elevation Model IdentificationComponent Locations Component Locations-BackGeneral Information Model Quantity Vent Size Burners Gas Valves Blowers FlueModel Burners per Valve Stages Fire at Stage General Safety Time/Temperature Relationships in ScaldsWater Time to Produce Serious Temp Burn Indoor Installations InstallationInstallation Codes Equipment BaseOutdoor Installations Heater Min. Clearance Recommended From CombustibleConventional Combustion Air Supply InstallationsCombustion and Ventilation Air Indoor UnitsGeneral Canadian InstallationsWater Piping Relief Valve PipingHydronic Heating Dual Boiler-Primary/Secondary Piping Air-Separation/Expansion Tank Domestic Hot Water PipingPiping-Heating Boilers Three-Way ValvesSingle Heater-Domestic Hot Water with One Storage Tank Automatic Chlorinators and Chemical Feeders Pool HeatingGas Supply Winterizing Your HeaterGas Supply Connection Gas Supply Pressure Gas Pressure RegulatorSurge Protection Electrical Power ConnectionsCheck the Power Source Making the Electrical ConnectionsElectrical Connections-Domestic Hot Water Single Stage and 2-Stage TankstatVenting Definition of Appliance CategoriesBarometric Damper Support of Vent StackVent Terminal Location Table I Vent/Air Inlet Termination Clearances US Installations Canada InstallationsVenting Installation Tips Venting ConfigurationsNatural Draft Vertical Venting System Installation Natural Draft Vertical Vent TerminationModel Appliance Certified Vent Size Max. Venting Category Inches Length feetHorizontal Thru-wall Direct Vent Termination Category Inches Length Certified Max Combustion Air Inlet Max. AirVenting Air Intake FeetHorizontal Thru-wall Direct Vent Termination Category Inches Min./Max Combustion Max. Air CertifiedVenting Height InchesOutdoor Installation Vertical Direct Vent System InstallationVertical Direct Vent Termination High Limit Manual Reset ControlsIgnition Control Module Flow Switch Low Water Cut Off OptionalWiring DIAGRAM-MODELS PRE-START-UP Initial START-UPMain Burner Adjustment Safety InspectionStart-Up Follow-Up Post START-UP CheckOperation Operating InstructionsTo Turn Off Gas To Appliance MaintenanceSuggested Minimum Maintenance Schedule Yearly Beginning of each heating seasonMonthly AppendixInside Combustion Air Contamination QuarterlyCorporate Headquarters Page
Related manuals
Manual 56 pages 23.48 Kb

122-322 specifications

Raypak 122-322 is a cutting-edge pool and spa heater designed for optimal performance and efficiency. Known for its robust construction and reliable heating capabilities, this heater has become a preferred choice among pool owners.

One of the standout features of the Raypak 122-322 is its advanced copper fin tube heat exchanger. This innovative technology enhances the heater's efficiency by maximizing heat transfer while minimizing energy consumption. By efficiently circulating the water through the heat exchanger, the Raypak 122-322 quickly raises the temperature, allowing for an enjoyable swimming experience regardless of the weather.

The heater is equipped with a digital control system that allows for precise temperature adjustments. This user-friendly interface makes it easy to set and maintain the desired water temperature, promoting user convenience. The digital controls also provide diagnostic features, which simplify troubleshooting and maintenance, ensuring the heater operates smoothly for years to come.

Safety is a crucial aspect of the Raypak 122-322. It comes with a series of safety features, including a flame rollout switch, high limit switch, and a pressure switch that ensures the unit operates safely under various conditions. This focus on safety provides peace of mind for users, knowing that their heating system is designed with protective measures in place.

The Raypak 122-322 is environmentally friendly, designed to use less energy compared to conventional heating systems. Its efficient performance not only reduces operational costs but also lessens the overall environmental impact, making it a responsible choice for conscious consumers.

With a compact design, the Raypak 122-322 can fit easily into various installation spaces, making it versatile for numerous residential or commercial settings. Additionally, the unit is built with durable materials resistant to corrosion and weather conditions, ensuring longevity and minimal maintenance requirements.

Overall, the Raypak 122-322 stands out in the market due to its advanced features, safety mechanisms, energy efficiency, and ease of use. It exemplifies a perfect blend of innovation and reliability, making it an exceptional option for anyone looking to enhance their pool or spa experience.