Raypak 122-322 General Information, Model Quantity Vent Size Burners Gas Valves Blowers Flue

Page 7

General Information

Model

 

 

Quantity of

 

 

 

 

 

Vent Size (in.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.

Burners

Gas Valves

 

 

Blowers

 

Flue

Intake

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

122

 

3

 

2*

 

 

 

1

 

4

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

162

 

4

 

2*

 

 

 

1

 

5

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

202

 

5

 

2*

 

 

 

1

 

5

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

242

 

6

 

2*

 

 

 

1

 

5

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

322

 

8

 

2*

 

 

 

1

 

6

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Second valve located inside air plenum

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table A: Basic Data

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model

 

Burners per Valve

 

 

 

Stages

 

 

 

% Fire at Stage

No.

 

A

 

B

 

1

 

 

2

 

1

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

122

 

2

 

1

 

A

 

AB

 

66

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

162

 

3

 

1

 

A

 

AB

 

75

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

202

 

3

 

2

 

A

 

AB

 

60

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

242

 

4

 

2

 

A

 

AB

 

66

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

322

 

5

 

3

 

A

 

AB

 

63

 

100

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Table B: Manifold Data

Fig. 5: Air Shutter Adjustment

Fig. 4: Gas Valve Detail

7

Image 7
Contents Installation & Operating Instructions Page Contents Are important but not related to personal injury hazards Model Identification Before InstallationInstallations at Elevation Product ReceiptComponent Locations-Back Component LocationsModel Quantity Vent Size Burners Gas Valves Blowers Flue General InformationModel Burners per Valve Stages Fire at Stage Time/Temperature Relationships in Scalds General SafetyWater Time to Produce Serious Temp Burn Equipment Base InstallationInstallation Codes Indoor InstallationsHeater Min. Clearance Recommended From Combustible Outdoor InstallationsIndoor Units InstallationsCombustion and Ventilation Air Conventional Combustion Air SupplyRelief Valve Piping Canadian InstallationsWater Piping GeneralHydronic Heating Dual Boiler-Primary/Secondary Piping Three-Way Valves Domestic Hot Water PipingPiping-Heating Boilers Air-Separation/Expansion TankSingle Heater-Domestic Hot Water with One Storage Tank Winterizing Your Heater Pool HeatingGas Supply Automatic Chlorinators and Chemical FeedersGas Pressure Regulator Gas Supply Connection Gas Supply PressureMaking the Electrical Connections Electrical Power ConnectionsCheck the Power Source Surge ProtectionSingle Stage and 2-Stage Tankstat Electrical Connections-Domestic Hot WaterDefinition of Appliance Categories VentingSupport of Vent Stack Barometric DamperVent Terminal Location Table I Vent/Air Inlet Termination Clearances Canada Installations US InstallationsVenting Configurations Venting Installation TipsNatural Draft Vertical Vent Termination Natural Draft Vertical Venting System InstallationCategory Inches Length feet Model Appliance Certified Vent Size Max. VentingHorizontal Thru-wall Direct Vent Termination Feet Certified Max Combustion Air Inlet Max. AirVenting Air Intake Category Inches LengthHorizontal Thru-wall Direct Vent Termination Height Inches Min./Max Combustion Max. Air CertifiedVenting Category InchesVertical Direct Vent System Installation Outdoor InstallationVertical Direct Vent Termination Controls High Limit Manual ResetIgnition Control Module Low Water Cut Off Optional Flow SwitchWiring DIAGRAM-MODELS Initial START-UP PRE-START-UPSafety Inspection Main Burner AdjustmentStart-Up Operating Instructions Post START-UP CheckOperation Follow-UpYearly Beginning of each heating season MaintenanceSuggested Minimum Maintenance Schedule To Turn Off Gas To ApplianceQuarterly AppendixInside Combustion Air Contamination MonthlyCorporate Headquarters Page
Related manuals
Manual 56 pages 23.48 Kb

122-322 specifications

Raypak 122-322 is a cutting-edge pool and spa heater designed for optimal performance and efficiency. Known for its robust construction and reliable heating capabilities, this heater has become a preferred choice among pool owners.

One of the standout features of the Raypak 122-322 is its advanced copper fin tube heat exchanger. This innovative technology enhances the heater's efficiency by maximizing heat transfer while minimizing energy consumption. By efficiently circulating the water through the heat exchanger, the Raypak 122-322 quickly raises the temperature, allowing for an enjoyable swimming experience regardless of the weather.

The heater is equipped with a digital control system that allows for precise temperature adjustments. This user-friendly interface makes it easy to set and maintain the desired water temperature, promoting user convenience. The digital controls also provide diagnostic features, which simplify troubleshooting and maintenance, ensuring the heater operates smoothly for years to come.

Safety is a crucial aspect of the Raypak 122-322. It comes with a series of safety features, including a flame rollout switch, high limit switch, and a pressure switch that ensures the unit operates safely under various conditions. This focus on safety provides peace of mind for users, knowing that their heating system is designed with protective measures in place.

The Raypak 122-322 is environmentally friendly, designed to use less energy compared to conventional heating systems. Its efficient performance not only reduces operational costs but also lessens the overall environmental impact, making it a responsible choice for conscious consumers.

With a compact design, the Raypak 122-322 can fit easily into various installation spaces, making it versatile for numerous residential or commercial settings. Additionally, the unit is built with durable materials resistant to corrosion and weather conditions, ensuring longevity and minimal maintenance requirements.

Overall, the Raypak 122-322 stands out in the market due to its advanced features, safety mechanisms, energy efficiency, and ease of use. It exemplifies a perfect blend of innovation and reliability, making it an exceptional option for anyone looking to enhance their pool or spa experience.