Raypak 122-322 manual Are important but not related to personal injury hazards

Page 4

WARNINGS - Pay Attention to These Terms

DANGER:

Indicates the presence of immediate hazards which will cause severe

 

personal injury, death or substantial property damage if ignored.

 

 

WARNING:

Indicates the presence of hazards or unsafe practices which could cause

 

severe personal injury, death or substantial property damage if ignored.

 

 

CAUTION:

Indicates the presence of hazards or unsafe practices which could cause

 

minor personal injury or product or property damage if ignored.

 

 

NOTE:

Indicates special instructions on installation, operation, or maintenance which

are important but not related to personal injury hazards.

 

 

 

DANGER: Make sure the gas on which the heater will operate is the same type as that specified on the heater rating plate.

WARNING: Should overheating occur or the gas supply valve fail to shut, do not turn off or disconnect the electrical supply to the heater. Instead, shut off the gas supply at a location external to the heater.

WARNING: Risk of electrical shock. More than one disconnect switch may be required to deenergize the equipment before servicing.

WARNING - CALIFORNIA PROPOSITION

65:This product contains chemicals known to the State of California to cause cancer, birth defects or other reproductive harm.

WARNING: This unit contains refractory ceramic fiber (RCF) insulation in the combustion chamber. RCF, as manufactured, does not contain respirable crystalline silica. However, following sustained exposure to very high temperatures (>2192F), the RCF can transform into crystalline silica (cristabolite). The International Agency for Research on Cancer (IARC) has classified the inhalation of crystalline silica (cristabolite) as carcinogenic to humans.

When removing the burners or heat exchangers, take precautions to avoid creating airborne dust and avoid inhaling airborne fibers. When cleaning spills, use wet sweeping or High Efficiency Particulate Air (HEPA) filtered vacuum to minimize airborne dust. Use feasible engineering controls such as local exhaust ventilation or dust collecting systems to minimize airborne dust. Wear appropriate personal protective equipment including gloves, safety glasses with side shields, and appropriate NIOSH certified respiratory protection, to avoid inhalation of airborne dust and airborne fiber particles.

WARNING: To minimize the possibility of improper operation, serious personal injury, fire, or damage to the heater:

Always keep the area around the heater free of combustible materials, gasoline, and other flammable liquids and vapors.

Heater should never be covered or have any blockage to the flow of fresh air to the heater.

WARNING: Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of the control system and any gas control which has been under water.

CAUTION: Operation of this heater in low- temperature systems requires special piping. Harmful internal condensation will occur if the inlet water temperature does not exceed 105°F. Warranty claims will be denied when condensation occurs.

CAUTION: If this heater is to be installed above radiation level, it must be provided with a low water cut-off device at the time of heater installation.

CAUTION: If this heater is to be installed in a negative or positive pressure equipment room, there are special installation requirements. Consult factory for details.

CAUTION: This heater requires forced water circulation when the burner is operating. See minimum and maximum flow rates. Severe damage will occur if the heater is operated without proper water flow circulation.

4

Image 4
Contents Installation & Operating Instructions Page Contents Are important but not related to personal injury hazards Before Installation Installations at ElevationProduct Receipt Model IdentificationComponent Locations Component Locations-BackModel Quantity Vent Size Burners Gas Valves Blowers Flue General InformationModel Burners per Valve Stages Fire at Stage Time/Temperature Relationships in Scalds General SafetyWater Time to Produce Serious Temp Burn Installation Installation CodesIndoor Installations Equipment BaseOutdoor Installations Heater Min. Clearance Recommended From CombustibleInstallations Combustion and Ventilation AirConventional Combustion Air Supply Indoor UnitsCanadian Installations Water PipingGeneral Relief Valve PipingHydronic Heating Dual Boiler-Primary/Secondary Piping Domestic Hot Water Piping Piping-Heating BoilersAir-Separation/Expansion Tank Three-Way ValvesSingle Heater-Domestic Hot Water with One Storage Tank Pool Heating Gas SupplyAutomatic Chlorinators and Chemical Feeders Winterizing Your HeaterGas Supply Connection Gas Supply Pressure Gas Pressure RegulatorElectrical Power Connections Check the Power SourceSurge Protection Making the Electrical ConnectionsElectrical Connections-Domestic Hot Water Single Stage and 2-Stage TankstatVenting Definition of Appliance CategoriesSupport of Vent Stack Barometric DamperVent Terminal Location Table I Vent/Air Inlet Termination Clearances US Installations Canada InstallationsVenting Installation Tips Venting ConfigurationsNatural Draft Vertical Venting System Installation Natural Draft Vertical Vent TerminationModel Appliance Certified Vent Size Max. Venting Category Inches Length feetHorizontal Thru-wall Direct Vent Termination Certified Max Combustion Air Inlet Max. Air Venting Air IntakeCategory Inches Length FeetHorizontal Thru-wall Direct Vent Termination Min./Max Combustion Max. Air Certified VentingCategory Inches Height InchesVertical Direct Vent System Installation Outdoor InstallationVertical Direct Vent Termination Controls High Limit Manual ResetIgnition Control Module Flow Switch Low Water Cut Off OptionalWiring DIAGRAM-MODELS PRE-START-UP Initial START-UPSafety Inspection Main Burner AdjustmentStart-Up Post START-UP Check OperationFollow-Up Operating InstructionsMaintenance Suggested Minimum Maintenance ScheduleTo Turn Off Gas To Appliance Yearly Beginning of each heating seasonAppendix Inside Combustion Air ContaminationMonthly QuarterlyCorporate Headquarters Page
Related manuals
Manual 56 pages 23.48 Kb

122-322 specifications

Raypak 122-322 is a cutting-edge pool and spa heater designed for optimal performance and efficiency. Known for its robust construction and reliable heating capabilities, this heater has become a preferred choice among pool owners.

One of the standout features of the Raypak 122-322 is its advanced copper fin tube heat exchanger. This innovative technology enhances the heater's efficiency by maximizing heat transfer while minimizing energy consumption. By efficiently circulating the water through the heat exchanger, the Raypak 122-322 quickly raises the temperature, allowing for an enjoyable swimming experience regardless of the weather.

The heater is equipped with a digital control system that allows for precise temperature adjustments. This user-friendly interface makes it easy to set and maintain the desired water temperature, promoting user convenience. The digital controls also provide diagnostic features, which simplify troubleshooting and maintenance, ensuring the heater operates smoothly for years to come.

Safety is a crucial aspect of the Raypak 122-322. It comes with a series of safety features, including a flame rollout switch, high limit switch, and a pressure switch that ensures the unit operates safely under various conditions. This focus on safety provides peace of mind for users, knowing that their heating system is designed with protective measures in place.

The Raypak 122-322 is environmentally friendly, designed to use less energy compared to conventional heating systems. Its efficient performance not only reduces operational costs but also lessens the overall environmental impact, making it a responsible choice for conscious consumers.

With a compact design, the Raypak 122-322 can fit easily into various installation spaces, making it versatile for numerous residential or commercial settings. Additionally, the unit is built with durable materials resistant to corrosion and weather conditions, ensuring longevity and minimal maintenance requirements.

Overall, the Raypak 122-322 stands out in the market due to its advanced features, safety mechanisms, energy efficiency, and ease of use. It exemplifies a perfect blend of innovation and reliability, making it an exceptional option for anyone looking to enhance their pool or spa experience.