Raypak 122-322 manual Controls, High Limit Manual Reset, Ignition Control Module

Page 33

CONTROLS

WARNING: Installation, adjustment and service of heater controls including timing of various operating functions must be performed by a qualified installer, service agency or the gas supplier. Failure to do so may result in control damage, heater malfunction, property damage, personal injury, or death.

WARNING: Turn off the power to the heater before installation, adjustment or service of the heater controls. Failure to do so may result in heater malfunction, property damage, personal injury, or death.

CAUTION: This appliance has provisions to be connected to more than one (1) supply source. To reduce the risk of electric shock, disconnect all such connections before servicing.

CAUTION: Risk of electric shock. More than one

(1)disconnect switch may be required to de- energize the equipment before servicing.

Fig. 22: Ignition Module

High Limit (Manual Reset)

The heater is equipped with a manual reset high limit temperature device. Push the reset button and adjust the setting to 30° F or 40° F above desired operating temperature.

Ignition Control Module

The interrupted proved ignition device conserves ener- gy. When additional heat is needed, the combustion air blower starts to purge all air from the combustion chamber for about 15 seconds. On proof of air flow, the air proving switch closes and the igniter is ener- gized, eliminating the fuel costs of maintaining a constant pilot.

Fig. 23: Manual Reset High Limit

To ensure safe operation, the gas valve cannot open until the pilot igniter is verified. The 100% igniter safe- ty is an electronic device which closes the main gas valve within 8/10 of a second whenever the flame is interrupted. Main burner is automatically lit when the device is powered and pre-purged. Unit performs its own safety check and opens the main valve only after the igniter is proven to be capable of ignition.

33

Image 33
Contents Installation & Operating Instructions Page Contents Are important but not related to personal injury hazards Installations at Elevation Before InstallationProduct Receipt Model IdentificationComponent Locations-Back Component LocationsGeneral Information Model Quantity Vent Size Burners Gas Valves Blowers FlueModel Burners per Valve Stages Fire at Stage General Safety Time/Temperature Relationships in ScaldsWater Time to Produce Serious Temp Burn Installation Codes InstallationIndoor Installations Equipment BaseHeater Min. Clearance Recommended From Combustible Outdoor InstallationsCombustion and Ventilation Air InstallationsConventional Combustion Air Supply Indoor UnitsWater Piping Canadian InstallationsGeneral Relief Valve PipingHydronic Heating Dual Boiler-Primary/Secondary Piping Piping-Heating Boilers Domestic Hot Water PipingAir-Separation/Expansion Tank Three-Way ValvesSingle Heater-Domestic Hot Water with One Storage Tank Gas Supply Pool HeatingAutomatic Chlorinators and Chemical Feeders Winterizing Your HeaterGas Pressure Regulator Gas Supply Connection Gas Supply PressureCheck the Power Source Electrical Power ConnectionsSurge Protection Making the Electrical ConnectionsSingle Stage and 2-Stage Tankstat Electrical Connections-Domestic Hot WaterDefinition of Appliance Categories VentingBarometric Damper Support of Vent StackVent Terminal Location Table I Vent/Air Inlet Termination Clearances Canada Installations US InstallationsVenting Configurations Venting Installation TipsNatural Draft Vertical Vent Termination Natural Draft Vertical Venting System InstallationCategory Inches Length feet Model Appliance Certified Vent Size Max. VentingHorizontal Thru-wall Direct Vent Termination Venting Air Intake Certified Max Combustion Air Inlet Max. AirCategory Inches Length FeetHorizontal Thru-wall Direct Vent Termination Venting Min./Max Combustion Max. Air CertifiedCategory Inches Height InchesOutdoor Installation Vertical Direct Vent System InstallationVertical Direct Vent Termination High Limit Manual Reset ControlsIgnition Control Module Low Water Cut Off Optional Flow SwitchWiring DIAGRAM-MODELS Initial START-UP PRE-START-UPMain Burner Adjustment Safety InspectionStart-Up Operation Post START-UP CheckFollow-Up Operating InstructionsSuggested Minimum Maintenance Schedule MaintenanceTo Turn Off Gas To Appliance Yearly Beginning of each heating seasonInside Combustion Air Contamination AppendixMonthly QuarterlyCorporate Headquarters Page
Related manuals
Manual 56 pages 23.48 Kb

122-322 specifications

Raypak 122-322 is a cutting-edge pool and spa heater designed for optimal performance and efficiency. Known for its robust construction and reliable heating capabilities, this heater has become a preferred choice among pool owners.

One of the standout features of the Raypak 122-322 is its advanced copper fin tube heat exchanger. This innovative technology enhances the heater's efficiency by maximizing heat transfer while minimizing energy consumption. By efficiently circulating the water through the heat exchanger, the Raypak 122-322 quickly raises the temperature, allowing for an enjoyable swimming experience regardless of the weather.

The heater is equipped with a digital control system that allows for precise temperature adjustments. This user-friendly interface makes it easy to set and maintain the desired water temperature, promoting user convenience. The digital controls also provide diagnostic features, which simplify troubleshooting and maintenance, ensuring the heater operates smoothly for years to come.

Safety is a crucial aspect of the Raypak 122-322. It comes with a series of safety features, including a flame rollout switch, high limit switch, and a pressure switch that ensures the unit operates safely under various conditions. This focus on safety provides peace of mind for users, knowing that their heating system is designed with protective measures in place.

The Raypak 122-322 is environmentally friendly, designed to use less energy compared to conventional heating systems. Its efficient performance not only reduces operational costs but also lessens the overall environmental impact, making it a responsible choice for conscious consumers.

With a compact design, the Raypak 122-322 can fit easily into various installation spaces, making it versatile for numerous residential or commercial settings. Additionally, the unit is built with durable materials resistant to corrosion and weather conditions, ensuring longevity and minimal maintenance requirements.

Overall, the Raypak 122-322 stands out in the market due to its advanced features, safety mechanisms, energy efficiency, and ease of use. It exemplifies a perfect blend of innovation and reliability, making it an exceptional option for anyone looking to enhance their pool or spa experience.