Second Edition • Third Printing | Operator's Manual |
|
|
|
|
Test Up/Down Functions and Function Enable
The audible warnings on this machine come from the same central alarm. The descent alarm sounds at 60 beeps per minute. The alarm that goes off when the machine is not level sounds at 180 beeps per minute.
7 Do not push the lift function enable button. Push and hold the platform up button.
Result: No function should operate.
8Push and hold the lift function enable button. Push and hold the platform up button.
Result: The platform should raise.
9Push and hold the lift function enable button. Push and hold the platform down button.
Result: The platform should lower. The descent alarm should sound while the platform is lowering.
Test the Auxiliary Lowering
10Push and hold the lift function enable button and raise the platform approximately 60 cm.
11Push in the red Emergency Stop button to shut off the engine.
12Pull out the red Emergency Stop button to the on position.
13Push and hold the lift function enable button. Push and hold the platform down button.
Result: The platform should lower.
14 Turn the key switch to platform control and restart the engine.
FUNCTION TESTS
At the Platform Controls
Test Emergency Stop
15Push in the platform red Emergency Stop button to the off position.
Result: No functions should operate.
16 Pull the red Emergency Stop button out to the on position.
Result: The green power light should come on.
Test the Horn
17 Push the horn button.
Result: The horn should sound.
Test Up/Down Functions and Function Enable
18Start the engine.
19Activate the up/down rocker switch in the direction indicated by the blue arrow.
Result: The platform should not raise.
20 Push and hold the lift function enable button.
21 Activate the up/down rocker switch in the direction indicated by the blue arrow.
Result: The platform should raise.
22Push and hold the lift function enable button.
23Activate the up/down rocker switch in the direction indicated by the yellow arrow.
Result: The platform should lower. The descent alarm should sound while the platform is lowering.
Part No.82828 | Genie | 17 |