Genie GS-3390 Emergency Stop, Starting the Engine, Operation From Ground, Operation From Platform

Page 24

Operator's Manual

Second Edition • Third Printing

 

 

 

 

OPERATING INSTRUCTIONS

Emergency Stop

Push in the red Emergency Stop button to the off position at the ground controls or the platform controls to stop all machine functions and turn the engine off.

Repair any function that operates when either red Emergency Stop button is pushed in.

Starting the Engine

1At the ground controls, turn the key switch to the desired position.

2Be sure both ground and platform control red Emergency Stop buttons are pulled out to the on position.

Gasoline/LPG models

3If desired, select LPG by pushing the LPG button.

4Push the engine start button.

Diesel models

3Push and hold the glow plug button for 3 to 5 seconds.

4Push the engine start button.

All models

If the engine fails to start after 15 seconds of cranking, determine the cause and repair any malfunction. Wait 60 seconds before trying to start again.

In cold conditions, -6°C and below, warm the engine for 5 minutes before operating to prevent hydraulic system damage.

In extreme cold conditions, -18°C and below, machines should be equipped with optional cold start kits. Attempting to start the engine when temperatures are below -18°C may require the use of a booster battery.

Gasoline/LPG models: In cold conditions, -6°C and below, the machine should be started on gasoline and warmed for 2 minutes, then switched to LPG. Warm engines can be started on LPG.

Operation From Ground

1Turn the key switch to ground control.

2Pull out the platform and ground red Emergency Stop buttons to the on position.

3Start the engine.

To Position Platform

1 Push and hold the lift function enable button.

2 Activate the up function or the down function.

Drive and steer functions are not available from the ground controls.

Engine Idle Select

Select the engine idle (rpm) by pressing the idle select button. There are three settings for engine idle.

·Indicator light off: low idle

·Indicator light blinking: high idle activated by any function enable button

·Indicator light on: high idle

Operation From Platform

1Turn the key switch to platform control.

2Pull out the platform and ground red Emergency Stop buttons to the on position.

3Start the engine.

22

Genie GS-3384 & GS-3390 & GS-4390 & GS-5390

Part No.82828

Image 24
Contents Operator’s Manual Contents Contact usSafety Rules Do Not Operate UnlessMachines without capacity indicator Machines with capacity indicatorElectrocution Hazards Tip-over HazardsMaximum capacity GS-4390 Maximum occupants Maximum allowable manual force Fall Hazards Collision Hazards Component Damage Hazards Explosion and Fire HazardsDamaged Machine Hazards Crushing HazardsOutrigger Safety Tip-over Hazards Battery Safety Burn HazardsExplosion Hazard Electrocution HazardPage Controls Ground Control PanelPlatform Controls Pre-operation Inspection FundamentalsPre-operation Inspection Maintenance Maintenance Symbols LegendObserve and Obey Check the BatteriesCheck the Engine Oil Level Scheduled Maintenance Check the Hydraulic Oil Level Check the Engine Coolant LevelFunction Tests At the Ground ControlsTest Emergency Stop Test Up/Down Functions and Function Enable At the Platform ControlsTest the Auxiliary Lowering Test the HornTest the Steering Test Drive and BrakingTest Limited Drive Speed Test the Up Limit Switch and the Outriggers GS-5390 Test the Tilt Sensor OperationTest Auxiliary Lowering Workplace Inspection Workplace InspectionOperating Instructions Only use the machine as it was intendedEmergency Stop Starting the EngineOperation From Ground Operation From PlatformTo Extend and Retract Platform Auxiliary LoweringOperation From Ground with Controller Outrigger Operation if equippedFall Protection After Each UseFree-wheel Configuration for Winching Transport and Lifting InstructionsSecuring to Truck or Trailer for Transit Lifting Instructions AxisDecals Decal InspectionEngine Side Ground Controls Specifications Floor Loading InformationSpecifications Stowed, maximum Km/h Platform raised, maximum 12.2 m/39 sec GS-5390 Distributed by