2.3AUTOMATIC CHOKE (GASOLINE ONLY)
The engine is equipped with an automatic choke that consists of two main components: a choke solenoid and prechoke.
◆2.3.1 CHOKE SOLENOID
During engine cranking (Start/Stop switch at START), a
◆2.3.2 PRECHOKE
The choke system also has a
2.4BEFORE STARTING THE ENGINE
NOTE:
Instructions and information in this manual assume the generator has been properly installed, connected, serviced, tested and adjusted by a qualified installation technician or installation contractor.
◆2.4.1 INSTALLATION
Generator installation must have been properly com- pleted so it complies with all applicable codes, stan- dards and regulations and with the manufacturer's recommendations.
◆2.4.2 ENGINE LUBRICATION
Have the engine crankcase properly serviced with the recommended oil before starting. Refer to Section 1.5.4 (Page 6) and Sections 3.1 and 3.2 (Page 12) for oil ser- vicing procedures and recommendations.
◆2.4.3 FUEL SUPPLY
The engine must have an adequate supply of proper fuel to operate. Before starting it, check that sufficient fuel is available.
NOTE:
Depending on the installation, the generator may have either a separate fuel tank, or it may “share” the vehicle engine’s fuel tank.
◆2.4.4 COOLING AND VENTILATING AIR
Air inlet and outlet openings in the generator com- partment must be open and unobstructed for contin- ued proper operation. Without sufficient cooling and ventilating airflow, the engine/generator quickly over- heats, which causes it to shut down and may damage the generator.
◆2.4.5 ENGINE EXHAUST GAS
Before starting the generator engine, you should be sure there is no way for exhaust gases to enter the vehicle interior and endanger people or animals. Close windows, doors and other openings in the vehi- cle that, if open, might permit exhaust gases to enter the vehicle.
DANGER
The generator engine releases DEADLY carbon
!monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concen- trations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOX- IDE POISONING ARE (a) inability to think coher- ently, (b) nausea, (c) vomiting, (d) twitching muscles, (e) throbbing temples, (f) dizziness, (g) headaches, (h) weakness, and (i) sleepiness. IF YOU EXPERIENCE ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMP- TOMS PERSIST, GET MEDICAL HELP. Shut down the generator and do not operate it until it has been inspected and repaired.
Any attempt to crank or start the engine before
!you have properly serviced it with the recom- mended oil may result in an engine failure.
DANGER
Never sleep in the vehicle while the genset is
!running unless the vehicle has a working carbon monoxide detector. The exhaust system must be installed in accordance with the genset installa- tion manual. Make sure there is ample fresh air when operating the genset in a confined area.