Generac 02010-2, 04164-2 Exhaust System, Fuel Supply Lines, Excess Flow Valve, Leakage Tests

Page 32

Section 2 – Installation

PRIMEPACT 50 Recreational Vehicle Generator

The greater the airflow through the carburetor ven- turi, the lower the pressure at the venturi throat. The lower the pressure at the venturi throat, the greater the diaphragm movement, and the greater the move- ment of the regulator valve. The more the regulator valve opens, the greater the gas flow that is propor- tional to airflow through the generator.

The following facts about the secondary regulator must be emphasized:

The regulator must be sensitive to venturi throat pressure changes throughout the operating range.

The regulator must be properly adjusted so it will stop the flow of gas when the engine is not running (no air flow through the carburetor).

The slightest airflow (and vacuum in the venturi throat) should move the regulator valve off its seat and permit gas to flow.

2.5.6 FUEL SUPPLY LINES

LP gas lines must be accessible, but protected against possible damage.

Do NOT connect electrical wiring to any LP gas fuel line or run wiring alongside the lines.

Route gas lines away from hot engine exhausts.

Retain gas lines with metal clamps that do not have sharp edges.

Install an approved length of flexible hose between the gaseous fuel solenoid valve and rigid fuel sup- ply lines. The flexible line must be nonmetallic, nonorganic and nonconductive. It must be approved for use with LP gas.

2.5.7 EXCESS FLOW VALVE

LP gas tanks should have an excess flow valve, according to NFPA 501C, Paragraph 3-4.4. This valve and the gas lines must be carefully sized so the valve will close when a fuel line is severed or broken. Consult the Natural-LP Gas Association for informa- tion and limitations of excess flow valves.

Manual shutoff valves on the supply tank and else- where in the system must be fully open when operat- ing the generator. The excess flow valve functions properly only if all valves are fully open.

2.5.8 LEAKAGE TESTS

Do not place the generator into service until you have properly tested the gas system for leaks. To test the system, you need a separate source of 12 volts DC to open the gaseous fuel solenoid valve.

The leak test must comply fully with NFPA, Paragraph 318. All connections, hoses, valve regula- tors, fittings, and other fuel system parts must be tested under gas or air pressure of not less than 90 psi (620 kPa), while using soap and water or an equivalent solution to check for leaks. Other approved methods of testing for leaks may be used, if appropriate. DO NOT USE ANY FLAME TO TEST FOR LEAKS.

DANGER

Gaseous fuel lines between the tank and the secondary regulator are under a positive pres- sure (about 11 inches water column). Gas pres- sure at the outlet side of the secondary regula- tor, however, is a negative pressure and can draw flame inside a line or fitting and cause an explosion.

2.6EXHAUST SYSTEM

The generator exhaust system must be safely and properly installed. Only approved mufflers and other exhaust system parts must be used. A properly installed exhaust system must be vapor tight, quiet and completely safe.

DANGER

The generator engine gives off DEADLY carbon

!monoxide gas through its exhaust system. This dangerous gas, if breathed in sufficient concen- trations, can cause unconsciousness or even death. Never operate the generator set with the vehicle inside any garage or other enclosed area. DO NOT OPERATE THE GENERATOR IF THE EXHAUST SYSTEM IS LEAKING OR HAS BEEN DAMAGED. SYMPTOMS OF CARBON MONOX- IDE POISONING ARE (a) inability to think coher- ently; (b) vomiting; (c) twitching muscles; (d) throbbing temples; (e) dizziness; (f) headaches;

(g) weakness; and (h) sleepiness. IF YOU FEEL ANY OF THESE SYMPTOMS, MOVE INTO FRESH AIR IMMEDIATELY. IF SYMPTOMS PERSIST, GET MEDICAL HELP. Do not operate the generator until its exhaust system has been inspected and properly repaired.

Never tee the generator engine exhaust pipe

!into the vehicle engine exhaust piping. This causes excessive back pressure on the genera- tor engine. Also, water from one engine can damage the other engine.

30 Generac® Power Systems, Inc.

Image 32
Contents Power SYSTEMS, INC Authorized Service Dealer Location IntroductionPart II Installation Instructions Table of ContentsGeneral Hazards Electrical Hazards Model 04164-2 Primepact 50LP Generator IdentificationModel 02010-2 Primepact Safety SpecificationsGenerator Applicability Generator AC Connection SystemOptional Propane Fuel System Fuel ConsumptionEngine OIL Requirements GeneratorSTART/STOP Switch Generator Control PanelOptional Remote START/STOP Panel Fuel PrimerAutomatic Choke Gasoline only Before Starting the EngineStarting the Generator Stopping the GeneratorApplying Loads to Generator SUMMER/WINTER Heat Riser SystemLOW OIL Pressure Switch High Temperature SwitchProtection Systems Do not Overload the GeneratorAdditional Information Checking the Engine OIL Level Changing the Engine OIL AND/OR OIL FilterMaintaining the Engine AIR Cleaner Clean AIR IntakeCleaning the Foam Precleaner Checking the Engine Spark PlugCleaning the Generator Battery MaintenanceSpark Arrestor Muffler WeeklyDrive Belt Exercising the GeneratorReturn to Service OUT of Service ProcedureRemoval from Service Part General Hazards Fire Hazards Purpose and Scope Manual Standards BookletsEquipment Description Generator Engine Operating SpeedMajor Features and Dimensions Location and Support Generator LocationGenerator Support Suspended MountingGenerator Compartments Generator RestraintCompartment Construction Compartment SizeAcoustics Sound Insulating MaterialsTypical Noise Abatement 2.2.5 Compartment Floor Cutouts Cooling AIR Inlet Openings Cooling and Ventilating AIRGenerator Airflow Compensating for Restrictions Testing the InstallationGasoline Fuel System LP GAS Fuel System Fuel Tank Flexible Fuel LineGenerator Fuel Supply Line Rigid Fuel LinesPrimary Regulator Some Important ConsiderationsVapor Withdrawal Gaseous CarburetionExhaust System Fuel Supply LinesExcess Flow Valve Leakage TestsExhaust System Safety Electrical ConnectionsMufflers and Spark Arrestors Type of Exhaust SystemWiring Isolating Different Power SourcesGenerator AC Connections ConduitPower Supply Cord Ground Fault Circuit InterruptersOptional Accessories Recommended BatteryBattery Cables Battery Cable ConnectionsPost Installation Tests Testing Under LoadBefore Initial START-UP Remote Panel ModelsInstallation Checklist Troubleshooting Guide Problem Cause CorrectionElectrical Data Electrical Data Exploded Views and Parts Lists QTY Description Exploded Views and Parts Lists REGULATOR, GAS Fuel Exploded Views and Parts Lists Lower Bearing Carrier Exploded Views and Parts Lists ¼/ M6-LOCK Washer To Starter SCROLL, Flywheel Exploded Views and Parts Lists Piston Ring SET Exploded Views and Parts Lists MANIFOLD, Intake Exploded Views and Parts Lists CARBURETOR, GN 410 L/P PURCHASER’S/OWNER’S Warranty Responsibilities Your Warranty Rights and ObligationsMANUFACTURER’S Emission Control System Warranty Coverage Emission Control System Warranty Emission Related Parts Include the FollowingWarranty Schedule CONSUMER/PERSONAL Applications This Warranty Shall not Apply to the Following