Generac 02010-0, 04164-0 owner manual Installation Checklist

Page 39

Section 3 – Post-installation Start-up Adjustments

PRIMEPACT 50 Recreational Vehicle Generator

3.5INSTALLATION CHECKLIST

LOCATION AND SUPPORT

Generator is properly located.

Generator is properly supported.

Generator is properly restrained.

GENERATOR COMPARTMENT

Compartment construction is proper.

Holes/Openings are vapor-sealed.

Compartment size is correct.

Compartment is vapor-sealed.

Sound insulation is correct.

Floor cutouts are properly completed.

COOLING AND VENTILATING AIR

Airflow is adequate.

Air inlet opening is correct.

Compensate for restrictions.

Check that installation has been tested.

GASOLINE FUEL SYSTEM

Fuel tank complies with all applicable codes.

Fuel system is properly installed and checked for leaks.

OPTIONAL LP GAS FUEL SYSTEM

Fuel system is properly installed and checked for leaks.

Pressure at regulator inlet is correct.

Rated flow of primary regulator is correct.

All parts are properly installed.

Fuel system is properly tested/adjusted.

EXHAUST SYSTEM

Exhaust system complies with all applicable codes.

Exhaust system is properly and safely installed.

ELECTRICAL CONNECTIONS

Connections comply with local code requirements and all National Electrical Codes.

Junction box is properly installed.

Wiring meets all standards.

All connections are correct.

Conduit is properly installed and sealed.

Generator is properly bonded to the vehicle.

BATTERY INSTALLATION

Recommended battery is installed.

Recommended cables are installed.

Cables are clean and tight.

Cables are connected properly.

Proper ventilation is provided.

Terminals are coated with anti-corrosion grease, and terminal covers are positioned.

OPTIONAL ACCESSORIES

Check that remote start/stop panels (if used) are installed properly.

Check that hourmeter kit (if used) is installed properly.

Check that any other options and accessories (if used) are installed properly.

POST INSTALLATION TESTS

Check that all tests are completed properly.

DATE OF INSTALLATION ____________________________________________________

NAME OF INSTALLER ______________________________________________________

SIGNATURE OF INSTALLER ________________________________________________

Generac® Power Systems, Inc. 37

Image 39
Contents Power SYSTEMS, INC Introduction Authorized Service Dealer LocationTable of Contents Part II Installation InstructionsGeneral Hazards Electrical Hazards Primepact 50LP Generator IdentificationModel PrimepactGenerator AC Connection System SafetySpecifications Generator ApplicabilityEngine Optional Propane Fuel SystemFuel Consumption Engine OIL RequirementsFuel Primer START/STOP SwitchGenerator Control Panel Optional Remote START/STOP PanelAutomatic Choke Gasoline only Before Starting the EngineStarting the Generator Stopping the Generator SUMMER/WINTER Heat Riser SystemLetting the Engine Stabilize Do not Overload the Generator LOW OIL Pressure SwitchHigh Temperature Switch Protection SystemsAdditional Information Changing the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelChecking the Engine Spark Plug Maintaining the Engine AIR CleanerClean AIR Intake Cleaning the Foam PrecleanerWeekly Cleaning the GeneratorBattery Maintenance Spark Arrestor MufflerExercising the Generator Drive BeltOUT of Service Procedure Removal from ServiceReturn to Service Part General Hazards Electrical Hazards Generator Engine Operating Speed Purpose and Scope ManualStandards Booklets Equipment DescriptionMajor Features and Dimensions Suspended Mounting Location and SupportGenerator Location Generator SupportCompartment Size Generator CompartmentsGenerator Restraint Compartment ConstructionSound Insulating Materials AcousticsTypical Noise Abatement 2.2.5 Compartment Floor Cutouts Cooling and Ventilating AIR Generator AirflowCooling AIR Inlet Openings Testing the Installation Gasoline Fuel SystemCompensating for Restrictions Rigid Fuel Lines LP GAS Fuel SystemFuel Tank Generator Fuel Supply LineGaseous Carburetion Primary RegulatorSome Important Considerations Vapor WithdrawalLeakage Tests Exhaust SystemFuel Supply Lines Excess Flow ValveType of Exhaust System Exhaust System SafetyElectrical Connections Mufflers and Spark ArrestorsConduit WiringIsolating Different Power Sources Generator AC ConnectionsGround Fault Circuit Interrupters Power Supply CordBattery Cable Connections Optional AccessoriesRecommended Battery Battery CablesRemote Panel Cables Remote Panel ModelsInitial Start Post Installation TestsTesting Under Load Before Initial START-UPInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Appendix 3 Electrical Data Appendix 4 Exploded Views and Parts Lists QTY. Description Appendix 4 Exploded Views and Parts Lists REGULATOR, GAS Fuel Appendix 4 Exploded Views and Parts Lists Lower Bearing Carrier Appendix 4 Exploded Views and Parts Lists Item Part no QTY. Description Appendix 4 Exploded Views and Parts Lists Piston Ring SET Appendix 4 Exploded Views and Parts Lists MANIFOLD, Intake Appendix 4 Exploded Views and Parts Lists BOLT, SHOULDER, M6 X 15 LG Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power SYSTEMS, INC