Generac 02010-0, 04164-0 owner manual QTY. Description

Page 45

Appendix 4 — Exploded Views and Parts Lists

PRIMEPACT 50 Recreational Vehicle Generator

Base and Pulleys (Model 02010-0) – Drawing No. A8924-B

ITEM

PART NO.

QTY. DESCRIPTION

 

ITEM

PART NO.

QTY. DESCRIPTION

1

C2368

1

BASE, MOUNTING

36

A4456

2

3/8" SPECIAL LOCK WASHER

2

53407

1

GROUND CABLE

37

90475

1

FUEL PUMP

3

46911

4

MOUNT, (RUBBER)

38

87769

1

FUEL FILTER

4

25017

6

CAPSCREW, HEX HD.-3/8"-16

39

A7695

1

FITTING-1/8" PIPE TO 1/4"

 

 

 

X 1/2"

 

 

 

 

TUBE

5

22237

6

LOCK WASHER-3/8"

40

A6922

1

FUEL TUBE, METAL

6

22129

7

LOCK WASHER-M8

41

79246

2

CAPSCR., HEX HD.-M6-1.0 X 16

7

A6479

1

SKID, RUBBER MOUNT

42

22145

5

FLAT WASHER-M8-5/16"

8

77603

2

SAFETY BOLT 5/16"-18 X 3 1/2"

43

38150

3

FLAT WASHER-#8

9

22259

2

NUT, HEX-5/16"-18

44

A8010A

1

GASKET, BLOWER HSNG

10

52858

6

NUT, FLANGED LOCK-M8-1.25

45

77643

1

EXHAUST PIPE GASKET

11

51730

2

CAPSCR. HEX HD.-M8-1.25 X

46

75237

4

WASHER, SPRING RETAINER

 

 

 

60MM

47

75763-A

1

BOOT, BATTERY CABLE

12

29459

2

SPRING, BELT TENSION

48

90859

1

EXHAUST COVER PLATE

13

75215

2

WASHER, SPRING CNTR.

49

30340

6 IN. HOSE, FUEL

14

73146

4

SLIDE (NYLON)

50

A8594

1

PAN, SLIDE

15

75209

2

SUPPORT, NYLON SLIDE

51

23762

2

SHAKEPROOF WASHER

16

A8341

1

MANIFOLD, EXHAUST

52

23152

2

CAPSCR., HEX HD.-3/8"-16 X

17

90239

1

GASKET, EXHAUST

 

 

 

 

3/4"

 

 

 

MANIFOLD

53

23762

1

SHAKEPROOF-M5

18

40976

2

SOCKET HD. CAPSCR.,-M8-

54

45756

2

SCREW, TAPTITE-M6-1.0 X 10

 

 

 

1.25 X 20 LG.

 

 

 

 

LG.

19

A6858

1

GASKET, COLLECTOR PAN

55

22131

1

FLAT WASHER-M10

20

A8614

1

SKID, RUBBER MOUNT

56

48031-C

2

CLAMP, HOSE

21

75224-B

1

PULLEY, ENGINE

57

81105

2

NUT, FLANGE-5/16"-18

22

73106-B

1

PULLEY, ALT.

 

 

 

 

(SPECIAL)

23

75216

1

BELT (POLY V 4L)-40"

58

66849

4

SCREW, TAPTITE M5-0.8 X 16

24

49451

1

WASHER, PULLEY RETAINER

 

 

 

 

LG.

25

42633

1

CAPSCR., SOCKET HD. 3/8"-24

59

86729

1

STARTER CONTACTOR

 

 

 

X 1" (GRADE 5)

60

A8010

1

GASKET, BLOWER HSNG

26

39253

3

CAPSCR., HEX HD.-M8-1.25 X

61

C2824

7

HHS #10-32 X 9/16" LG, TAP-R

 

 

 

20

62

10-74260

1

STARTER CABLE

27

A8250

1

CAPSCR., HEX HD.-3/8"-24 X 2"

63

22127

2

HEX NUT-1/4"-20

28

56893

7

CRIMPTITE-#10-24 X 1/2"

64

22097

2

LOCK WASHER-1/4"

29

A8615

1

BRACKET-FUEL PUMP

65

22264

2

LOCK WASHER-M4

30

C1320

1

HOUSING, BLOWER

66

22471

2

HEX NUT-#8-32

31

63036

3

CRIMPTITE-#8-18 X 1/4"

67

A8531

1

PLATE, BLOWER SIDE

32

A8694

1

SCREEN, SLIDE PAN

68

A8407

1

GASKET, BLOWER SIDE

33

A8726

1

GASKET, BLOWER / PAN

69

22473

1

FLAT WASHER ¼"

34

75242

4

SPRING, GENERATOR SET MT

 

 

 

 

 

35

C4006

1

CABLE, BATTERY

 

 

 

 

 

Generac® Power Systems, Inc. 43

Image 45
Contents Power SYSTEMS, INC Introduction Authorized Service Dealer LocationTable of Contents Part II Installation InstructionsGeneral Hazards Electrical Hazards Model Generator IdentificationPrimepact Primepact 50LPSpecifications SafetyGenerator Applicability Generator AC Connection SystemFuel Consumption Optional Propane Fuel SystemEngine OIL Requirements EngineGenerator Control Panel START/STOP SwitchOptional Remote START/STOP Panel Fuel PrimerAutomatic Choke Gasoline only Before Starting the EngineStarting the Generator Stopping the Generator SUMMER/WINTER Heat Riser SystemLetting the Engine Stabilize High Temperature Switch LOW OIL Pressure SwitchProtection Systems Do not Overload the GeneratorAdditional Information Changing the Engine OIL AND/OR OIL Filter Checking the Engine OIL LevelClean AIR Intake Maintaining the Engine AIR CleanerCleaning the Foam Precleaner Checking the Engine Spark PlugBattery Maintenance Cleaning the GeneratorSpark Arrestor Muffler WeeklyExercising the Generator Drive BeltOUT of Service Procedure Removal from ServiceReturn to Service Part General Hazards Electrical Hazards Standards Booklets Purpose and Scope ManualEquipment Description Generator Engine Operating SpeedMajor Features and Dimensions Generator Location Location and SupportGenerator Support Suspended MountingGenerator Restraint Generator CompartmentsCompartment Construction Compartment SizeSound Insulating Materials AcousticsTypical Noise Abatement 2.2.5 Compartment Floor Cutouts Cooling and Ventilating AIR Generator AirflowCooling AIR Inlet Openings Testing the Installation Gasoline Fuel SystemCompensating for Restrictions Fuel Tank LP GAS Fuel SystemGenerator Fuel Supply Line Rigid Fuel LinesSome Important Considerations Primary RegulatorVapor Withdrawal Gaseous CarburetionFuel Supply Lines Exhaust SystemExcess Flow Valve Leakage TestsElectrical Connections Exhaust System SafetyMufflers and Spark Arrestors Type of Exhaust SystemIsolating Different Power Sources WiringGenerator AC Connections ConduitGround Fault Circuit Interrupters Power Supply CordRecommended Battery Optional AccessoriesBattery Cables Battery Cable ConnectionsRemote Panel Cables Remote Panel ModelsTesting Under Load Post Installation TestsBefore Initial START-UP Initial StartInstallation Checklist Appendix 1 Notes Problem Cause Correction Troubleshooting GuideAppendix 3 Electrical Data Appendix 3 Electrical Data Appendix 4 Exploded Views and Parts Lists QTY. Description Appendix 4 Exploded Views and Parts Lists REGULATOR, GAS Fuel Appendix 4 Exploded Views and Parts Lists Lower Bearing Carrier Appendix 4 Exploded Views and Parts Lists Item Part no QTY. Description Appendix 4 Exploded Views and Parts Lists Piston Ring SET Appendix 4 Exploded Views and Parts Lists MANIFOLD, Intake Appendix 4 Exploded Views and Parts Lists BOLT, SHOULDER, M6 X 15 LG Your Warranty Rights and Obligations MANUFACTURER’S Emission Control System Warranty CoveragePURCHASER’S/OWNER’S Warranty Responsibilities Emission Related Parts Include the Following Emission Control System WarrantyGenerac Power SYSTEMS, INC